6. Installation and use procedures
To change... Then...
Function of inputs
and outputs
Click Settings > Digital Input-Output
Muting Click Settings > Muting
Sensor inclination Loosen the side screws on the sensor and orient the sensors to the desired
inclination.
Sensor number and
positioning
Click Configuration
4. Click APPLY CHANGES.
5. Upon conclusion of transfer of the configuration to the control unit, click to print the report.
6.4.3 Back up the configuration
The current configuration can be backed up, including the input/output settings. The configuration is saved in a
.cfg file, which can be used to restore the configuration or to facilitate configuration of several SBV System Series.
1. In Settings > General, click BACKUP.
2. Select the file destination and save.
6.4.4 Load a configuration
1. In Settings > General, click RESTORE.
2. Select the previously saved .cfg file (see "Back up the configuration" above) and open it.
Note: a re-imported configuration requires new downloading onto the control unit and approval according
to the safety plan.
6.4.5 Display previous configurations
In Settings, click Activity History and then click Configuration reports page: the reports archive opens.
In Configuration click .
6.5 Other functions
6.5.1 Change language
1. Click .
2. Select the desired language. The language changes automatically.
6.5.2 Application type selection
In Settings > General > Application type selection.
6.5.3 Locate the area with detected motion
Click Validation: the area with detected motion turns red. The detection position appears on the left.
6.5.4 Restore factory default settings
In Settings > General click FACTORY RESET: the configuration parameters are restored to the default settings
and the admin password is reset.
WARNING! The factory configuration is not a valid configuration. Therefore, the system goes into an
alarm status. The configuration must be validated, and if necessary modified, through the Inxpect
Safety application by clicking APPLY CHANGES.
For the default values of the parameters, see "Parameters" on page91.
6.5.5 Identify a sensor
In Settings > Node IDAssignment or Configuration, click Identify near the desired sensor Node ID: the LED on
the sensor flashes for 5 seconds.