Instruction Manual

Table Of Contents
LED Status
Inxpect Safety
application messages
Problem Remedy
S6 Steady red FEE ERROR, FLASH
ERROR or RAM ERROR
Configuration saving
error, configuration not
performed or memory
error
Reconfigure or configure the
system, see "Manage the
configuration" on page61.
If the error persists, please contact
assistance service.
S1–S6
together
Steady red FIELDBUS ERROR Communication error
on the Fieldbus
At least one input or output is
configured as Fieldbus controlled.
Check that the cable is correctly
connected, communication with the
host is correctly established and the
exchanged data are maintained
passivated by the host itself.
S1–S5
together
Steady red DYNAMIC
CONFIGURATION ERROR
Error in the selection of
the dynamic
configuration: invalid
ID
Check the preset configurations
within the Inxpect Safety
application.
S1–S4
together
Steady red SENSOR
CONFIGURATIONERROR
Error during the
configuration of the
sensors
Check the sensors connected and
try again to perform the
configuration of the system via the
Inxpect Safety application.
At least
one LED
Flashing
red
"Sensor LED" on the next
page
Sensor corresponding
to the flashing LED in
error ** ("Sensor LED"
on the next page)
Check the problem through the LED
on the sensor.
At least
one LED
Flashing
green
"Sensor LED" on the next
page
Sensor corresponding
to the flashing LED in
error ** ("Sensor LED"
on the next page)
If the issue persists longer than one
minute, please contact assistance
service.
All the
LEDs
Steady
orange
- The system is starting
up.
Wait for a few seconds.
All the
LEDs
Flashing
green one
after the
other in
sequence
The control unit is in
boot state.
Please contact assistance service.
Note: fault signal on the control unit (steady LED) takes priority over a faulty sensor signal. For the status of the
single sensor, check the sensor LED.
Note*: S1 is the first from the top.
Note**: S1 corresponds to the sensor with ID 1, S2 corresponds to the sensor with ID 2 and so on.
7.1.2 Sensor LED
Status
Inxpect Safety application
messages
Problem Remedy
Steady
purple
- Sensor in boot state Perform a sensor firmware update or
contact technical support.
Flashing
purple *
- Sensor receiving a
firmware update
Wait for the update to be completed
without disconnecting the sensor.
Flashing
red. Two
flashes
followed by
a pause **
CANERROR Sensor without a valid
identifier assigned
Assign a Node ID to the sensor, see
"Connect the control unit to the
sensors" on page57.
Flashing
red. Three
flashes
followed by
a pause **
CANERROR Sensor does not receive
valid messages from
the control unit
Verify the connection of all sensors in
the chain since the last sensor in error
7. Maintenance and troubleshooting
SBV System Series| Instruction manual v1.2 DEC 2021|SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA
65