Instruction Manual
Table Of Contents
- Glossary of terms
- 1. This manual
- 2. Safety
- 3. Get to know SBV System Series
- 4. Functioning principles
- 4.1 Sensor functioning principles
- 4.2 Detection fields
- 4.3 Safety working modes and safety functions
- 4.4 Safety working mode: Both (default)
- 4.5 Safety working mode: Always access detection
- 4.6 Safety working mode: Always restart prevention
- 4.7 Restart prevention function: static object detection option
- 4.8 Features of the restart prevention function
- 4.9 Muting
- 4.10 Anti-tampering functions: anti-rotation around axes
- 4.11 Anti-tampering functions: anti-masking
- 5. Sensor position
- 6. Installation and use procedures
- 7. Maintenance and troubleshooting
- 8. Technical references
- 9. Appendix
7.3.12 Session authentication
The status of the session authentication and the interface used (USB/ETH) are logged.
Format: Session OPEN/CLOSE/WRONG PASSWORD/UNSET PASSWORD/TIMEOUT/CHANGE PASSWORD via
USB/ETH
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL UNIT Session OPEN via USB
7.3.13 Validation
Every time a validation activity starts or ends on the device, it is logged. The interface used (USB/ETH) is logged
as well.
Format: Validation STARTED/ENDED via USB/ETH
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL UNIT Validation STARTED via USB
7.3.14 Log download
Every time a log download is performed on the device, it is logged. The interface used (USB/ETH) is logged as
well.
Format: Log download via USB/ETH
Example:
20 2020/11/18 16:47:25 [INFO] CONTROL UNIT Log download via USB
7.4 ERRORevents (control unit)
7.4.1 Introduction
A diagnostic error is logged every time the periodic diagnostic functions detect a coming or going fault on the
control unit.
7.4.2 Temperature errors (TEMPERATUREERROR)
Error Meaning
BOARD TEMPERATURE TOOLOW Board temperature below minimum
BOARD TEMPERATURETOOHIGH Board temperature above maximum
7.4.3 Control unit voltage errors (POWERERROR)
Error Meaning
Control unit voltage
UNDERVOLTAGE
Undervoltage error for the indicated voltage
Control unit voltage
OVERVOLTAGE
Overvoltage error for the indicated voltage
ADC CONVERSION
ERROR
(only for the ADC) ADC conversion error in the micro-controller
The following table describes the control unit voltage:
Screen printing Description
VIN Power supply voltage (+24 V dc)
V12 Internal supply voltage
7. Maintenance and troubleshooting
SBV System Series| Instruction manual v1.2 DEC 2021|SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA
73