FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters
To the owner: INSTALLATION Thank you for purchasing an OMEGA FPD Series Flowmeter. Please take a few minutes to read through the manual before installing and operating your meter. If you have any problems with the meter, refer to the Maintenance and Troubleshooting sections of the manual. 1. Use thread sealant on all pipe threads. 2. Ensure the meter is installed so that rotor shafts are always in a horizontal plane (See Figure 1). Flow is bi-directional.
Reed Relay Specifications Reassembly: • Two wire SPST N/O. • Switching voltage 150 VDC; maximum current 0.25 Amps. 1. Replace rotors into the meter body. The rotors should be at 90 degrees to each other. • Rating 3 watts. • Duty cycle 20% ON, 80% OFF. 2. Lightly rotate the rotors by hand. They must rotate freely. Figure 3 3. Install O-ring. 1 4. Replace the meter cap and tighten the eight screws uniformly to 35Nm (25 Ft. Lbs.). 5. Replace the pulser cap and tighten the four screws.
TROUBLESHOOTING Symptom Probable Cause Corrective Action FLUID WILL NOT FLOW THROUGH THE METER 1. Foreign matter blocking rotors Dismantle meter, clean rotors. Strainer must be fitted in-line. 2. Line strainer blocked Clean strainer. 3. Damaged rotors Replace rotors. Strainer must be fitted in-line. 4. Meter connections overtightened Re-adjust connections. 1. Line strainer partially blocked Clean strainer. 2. Fluid is too viscous Maximum viscosity 1000 centipoise. 1.
DISPLAY PARTS LISTING Model: FPD1202-HP 3 4 TERMINAL BLOCK 9 10 2 6 7 8 1 u = Recommended Spare Parts to stock. Bold Text = Indicates Stainless Steel model parts. Item No. Qty. 1 2 3 3 4 6 6 7 8 8 9 10 1 8 1 1 4 1 1 2 1 1 1 1 Rec.
SPECIFICATIONS Pulse Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise Below 5 centipoise Accuracy of Reading Maximum Viscosity Maximum Operating Pressure Maximum Operating Temperature Pulse Type Pulses per Litre/Gallons Meter Dimensions Weight 2 to 100 / 0.53 to 26.4 5 to 100 / 1.32 to 26.4 ± 1% 1000 Centipoise 55160 kPa / 8000 PSI / 551 Bar 120°C / 248°F Hall Effect Sensor / Reed Switch 1000 / 3785 86mm Dia. / 3.4” Dia. (Meter Body) 83mm / 3.25” (Port Face to Face) 3.3 kg / 116 oz.
DISPLAY PARTS LISTING Model: FPD1203-HP 3 4 TERMINAL BLOCK 9 10 2 6 7 8 1 u = Recommended Spare Parts to stock. Bold Text = Indicates Stainless Steel model parts. Item No. Qty. 1 2 3 3 4 6 6 7 7 7 7 8 8 9 10 1 8 1 1 4 1 1 2 2 2 2 1 1 1 1 Rec.
SPECIFICATIONS Pulse Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise Below 5 centipoise Accuracy of Reading Maximum Viscosity* Maximum Operating Pressure Maximum Operating Temperature Pulse Type Pulses per Litre/Gallons Meter Dimensions Weight 15 to 500 / 4.0 to 132 25 to 500 / 6.0 to 132 ± 1% 1000 Centipoise 55160 kPa / 8000 PSI / 551 Bar 120°C / 248°F Hall Effect Sensor / Reed Switch 400 / 1514 86mm Dia. / 3.4” Dia. (Meter Body) 83mm / 3.25” (Port Face to Face) 3.3 kg / 116 oz.
M-4125 / 0405