INSTALLATION:
Drill a 1/8”inch hole into PVC Pipe 4” inches above the pumps discharge.
Do not work on pump until power is unplugged.
Do not cut off ground pin or use an adapter fitting.
Do not use an extension cord.
The pump power cord should be connected to a separately fused, grounded line with a minimum capacity of 15 amps.
It can be connected to non- fuse breaker as the recommended amperes.
Never touch the pump when it is connected to electrical power.
1. Before installing or servicing this pump, be certain pump power source is disconnected.
2. Installation and electrical wiring must adhere to state and local codes and must be completed before priming pump.
Check appropriate community agencies, or contact local electrical and pump professionals.
3. Call an electrician when in doubt. Pump should be connected to a separate 15 amps circuit breaker or 15 amp fuse block.
Note that, plugging into existing outlets may cause low voltage at motor, causing blown fuses, tripping of motor overload,
or burned out motor.
4. A permanent ground connection from pump to the grounding bar at the service panel is mandatory, StormPro sump
pumps come with a grounding conductor and a grounding-type attachment plug.
Do not connect pump to a power supply until permanently grounded. For maximum safety, connect pump to a circuit
equipped with a fault interrupter device when you position the pump's grounding wire.
5. Voltage of power supply must match the voltage of the pump.
6. Before installing pump, clear sump basin of any water, debris or sediment.
Warning: Sump basin must be vented in accordance with local plumbing codes. StormPro Sump pumps are not
designed for and CANNOT be installed in locations classified as hazardous
7. The following may cause severe damage to pump and will void the warranty:
(a) Using an extension cord.
(b) Cutting off the ground pin or using an adapter fitting.
(c) Working on pump or switch while plugged in.
(d) Removing motor housing, unscrewing impeller, or otherwise removing impeller seal
(e) Running the pump continuously.
(f) Pumping chemicals or corrosive liquids.
(g) Pumping gasoline or other flammable liquids.
(h) Piping, plastic PVC pipe could be installed in the outlet piping, but drain hose, galvanized steel or copper pipe may
be used if desired. All piping must be clean and free of all foreign matter to prevent clogging.
Use thread compound on all threaded joints unless specified otherwise. Be sure to seal the thread connection with
tape when your using the pipe fitting to connect the flange.
(i) Pump will be inadequate if suspension liquids contain solid particles larger than the strainer's holes.
ELECTRICAL WIRE CONNECTION:
WARNING
Verify that the voltage and frequency of the pump shown on the nameplate correspond to those available
on the mains.
The installer must make sure that the electric system is grounded in accordance with the law in force.
It is necessary to use cable with a length of 10m for outdoors. The plug and connections should be protected from
water splashes. Before using the pump, always inspect it visually (especially power cable and plug).
Do not use the pump if it is damaged.
If the pump is damaged, have it inspected by an authorized service center only.
Make sure that electric connections are protected from inundation. Protect the plug and the power cable from heat, oil
or sharp edges.
WARNING
The power cable must be replaced by qualified personnel only.
Grounding: The plug of the power cable has a double grounding contact, so that grounding can be
performed by simply inserting the plug
OVERLOAD PROTECTION:
This pump series has a built in thermal protection switch. The pump stops if an overload condition occurs.
The motor restarts automatically after it has cooled down
WARNIN