Product Manual

ion Genesis Pump Controller USER’SGUIDE
DigitalLevelControlWithPumpAlternationAnd Dated:04/16/2010
HighWaterAlarm Supersedes:04/12/2010
DocumentNo.:IONG-OM Page1of7
Visitusat
www.ionnation.us
TheionGenesisisaresidentialsumppumpcontroller
for1or2pumpsthatincludesredundantwaterlevel
sensors, a configurable water level/pump turn-on
setting,2-pumpalternation,pumpfailuresensing,local
audible/visualalarmnotication,andoptionalremote
alarmnotication.
This product is for use with manual pumps only. A
manual pump is a pump that runs when plugged into an
outlet. Sensors are supplied with this unit for control.
Indicators
Thefrontpanelhaslights,adisplay,andasounderto
offerdirectfeedbacktothehomeowner.
Buttons
Thefrontofthecontrollerhasbuttonslabeled“RESET/
TEST”and“PUMPTURNONLEVEL”.
TheRESET/TESTbuttonhastwofunctionsandmay
be depressed while no pumps are running. When
pushed, it runs the rst pump temporarily, followed
bythesecondpumpifitexists.Thiscanbeusedfor
pumptroubleshooting,andthecontrollerwillremember
howmanypumpsareavailableforfutureuse.This
buttonmustbepushedonceafterremovingoradding
anypumps.
ThePUMPTURNONLEVELbuttonssetthe water
level at which the pump(s) turns on. This level is
measuredininches,upfromthemiddleofthelower
watersensor(seetheInstallationsection).Whenthe
waterlevelispumpeddowntothemiddleofthelower
water sensor, the running pump is turned off. This
settingonlypertainstothelowerwaterlevelsensor.
Patentpending
WARNING: To prevent fire or shock
hazard,donotexposethisproducttorain
ormoisture.ThisproducthasaNEMA-1
rated enclosure for use in an indoor environment.
Neverspillliquidofanykindontheproduct.
CAUTION: Risk of electric shock. To
reduceriskofelectricshock,donotremove
cover.Therearenouserserviceableparts
inside.Referservicingtoqualiedservicepersonnel.
CAUTION: To prevent electric shock,
ensureproductisconnectedtoagrounded
outlet. The electrical outlet should be
properlywiredtoadedicated15-ampcircuitbreaker.
Proper short-circuit and overload protection must
be provided at the distribution panel. Install in
accordancewithalllocalandnationalelectricalcodes.
Recommendedmountingisaboveoorlevel.Forbest
performance,donotuseelectricalextensioncords.
Safety PrecautionS
table of contentS
SafetyPrecautions..........................1
GeneralOverview..........................1
Installation.................................2
Setup....................................3
Operation..............................3
Troubleshooting.........................4
Accessories...........................4
Specications..............................4
General overview