Product Manual
ion Genesis Pump Controller USER’SGUIDE
DigitalLevelControlWithPumpAlternationAnd Dated:04/16/2010
HighWaterAlarm Supersedes:04/12/2010
DocumentNo.:IONG-OM Page1of7
Visitusat
www.ionnation.us
TheionGenesisisaresidentialsumppumpcontroller
for1or2pumpsthatincludesredundantwaterlevel
sensors, a configurable water level/pump turn-on
setting,2-pumpalternation,pumpfailuresensing,local
audible/visualalarmnotication,andoptionalremote
alarmnotication.
This product is for use with manual pumps only. A
manual pump is a pump that runs when plugged into an
outlet. Sensors are supplied with this unit for control.
Indicators
Thefrontpanelhaslights,adisplay,andasounderto
offerdirectfeedbacktothehomeowner.
Buttons
Thefrontofthecontrollerhasbuttonslabeled“RESET/
TEST”and“PUMPTURNONLEVEL”.
TheRESET/TESTbuttonhastwofunctionsandmay
be depressed while no pumps are running. When
pushed, it runs the rst pump temporarily, followed
bythesecondpumpifitexists.Thiscanbeusedfor
pumptroubleshooting,andthecontrollerwillremember
howmanypumpsareavailableforfutureuse.This
buttonmustbepushedonceafterremovingoradding
anypumps.
ThePUMPTURNONLEVELbuttonssetthe water
level at which the pump(s) turns on. This level is
measuredininches,upfromthemiddleofthelower
watersensor(seetheInstallationsection).Whenthe
waterlevelispumpeddowntothemiddleofthelower
water sensor, the running pump is turned off. This
settingonlypertainstothelowerwaterlevelsensor.
Patentpending
WARNING: To prevent fire or shock
hazard,donotexposethisproducttorain
ormoisture.ThisproducthasaNEMA-1
rated enclosure for use in an indoor environment.
Neverspillliquidofanykindontheproduct.
CAUTION: Risk of electric shock. To
reduceriskofelectricshock,donotremove
cover.Therearenouserserviceableparts
inside.Referservicingtoqualiedservicepersonnel.
CAUTION: To prevent electric shock,
ensureproductisconnectedtoagrounded
outlet. The electrical outlet should be
properlywiredtoadedicated15-ampcircuitbreaker.
Proper short-circuit and overload protection must
be provided at the distribution panel. Install in
accordancewithalllocalandnationalelectricalcodes.
Recommendedmountingisaboveoorlevel.Forbest
performance,donotuseelectricalextensioncords.
Safety PrecautionS
table of contentS
SafetyPrecautions..........................1
GeneralOverview..........................1
Installation.................................2
Setup....................................3
Operation..............................3
Troubleshooting.........................4
Accessories...........................4
Specications..............................4
General overview