Ion+ Manual
Ion+
®
Digital Level Control Switch With Alarm
OPERATION MANUAL
Dated: 08/01/2013
Document Name: Ion+_OM
Page 1 of 4
www.ionstormpro.com
Patent pending
Features
1. First of its kind, solid-state sensing technology
with no moving parts with built in high water
alarm.
2. Space age design with no mechanical contact
points.
3. Green light indicates power, orange light
indicates pump is activated, red light indicates
high water alarm.
4. Built in dry contacts for remote alarm monitoring.
5. Multipoint sealing mechanism that supersedes
single surface seals.
6. Inverter rated for use with battery backup
systems.
7. Standard piggy-back style connection for use
with manual pumps.
8. Suitable for sump and certain sewage
applications.
9. System provides integrated monitoring and
alarm.
PiPe Mounting Bracket (oPtional)
1. Determine bracket mounting position (Figure
A).
2. Mount bracket to Ion+
®
switch with screw
already provided in Ion+
®
switch (Figure B).
3. Mount Hose Clamp with switch around pipe
at predetermined level. Cable should remain
outside hose clamp (Figure C).
4. Tighten hose clamp.
Note: The Ion+
®
switch is available in 6" range. The
range of the switch is the distance between the On
and Off levels. The Off level is at the bracket mounting
screw of the switch.
CAUTION: Bottom of switch should not be
mounted lower than suction inlet of pump.
When installing the Ion+
®
switch with the pipe
mounted bracket be sure not to set the switch too low
or too high on the pipe. The Ion+
®
must be installed
above the inlet of the pump to prevent air-locking as
shown in the installation drawing.
To prevent ooding do not set the on point of the
switch higher than the top of the basin.
Model Cord Range
INP20306 10 ft 6 in
INP20376 20 ft 6 in
Piggy-Back installation
Electrical outlet must not be located in pump pit.
Electrical outlet voltage, piggy-back plug voltage and
pump voltage must all be the same voltage.
DO NOT CUT plug off unit.
Ensure vent tube on plug is protected from moisture,
dirt and insects and other items that could plug or
block tube.
1. Insert the Ion+
®
switch’s piggy-back plug into
the outlet.
2. Plug pump into piggy-back plug (Figure E).
3. Allow system to cycle to ensure proper
installation.
Please note this product may not work in
conjunction with other controllers.
Note: The Ion+
®
switch does not operate like a
standard pressure switch. There are no contacts to
wear out, so when pressure is applied, there will not