Spec Sheet
Battery Backup System Features
• Primary pump with high eciency oil lled motor that
uses half the power of most ⅓ HP pumps
• Piggyback Ion digital level control primary switch with no
moving parts
• High quality 2100DC battery backup pump rated for
2,100 GPH
• Backup pump base keeps the pump o the bottom of
the basin to avoid clogging from debris
• Heavy duty adjustable vertical backup oat switch for
maximum reliability
• Solid state 8 amp charger unit with 5 charging stages
automatically switches to DC mode when power is out
• Built-in audible alarm and indicator lights on charger for
added protection
• Uses one 12 volt deep cycle AGM battery (battery is NOT
included)
• 1½" Sch. 40 PVC piping
• Check valve on each pump and a combination valve on
the main discharge
• 3 year warranty
JSPII
Typical Installation Diagram
1. Battery box with DC charger
2. ⅓ HP primary pump
3. Ion
®
digital level control switch
4. Backup pump
5. Backup vertical switch
6. Stand (optional)
1
4
5
2
3
Primary Pump Specications
Typical Applications
• Residential sump
• Dewatering
Maximum Capacity Up to 45 GPM
Maximum Head Up to 24′
Electrical Data 115 V, 1 Ø, 4 FLA, 60 Hz
Motor Data
⅓ HP, PSC, high eciency
motor with thermal overload
protection, 3450 RPM
Recommended
Minimum Basin Size
18″ x 24″
Automatic Operation i: Ion Digital Level Control
Materials of
Construction
Cast iron and engineered
thermoplastic
Impeller Thermoplastic vortex
Power Cord 10′ Standard
Discharge 1½″ NPT
Solids Handling ½″
Preassembled Sump & Battery Backup System
Revised: 08.20.14 11:34
6
Capacity (GPM)
Total Dynamic Head (ft.)
30
25
20
15
10
5
0
0 5 10 15 20 25 30 35 40 45
Pump Performance