Controller Manual
Ion Genesis
®
II Pump Controller
Digital Level Control with Pump Alternation
and High Water Alarm
OPERATION MANUAL
Dated: 07/10/2017
Document Name: IonGenesisII_OM
Page 1 of 8
www.ionproducts.net
Note: This product is intended to be installed by
experienced professionals only.
Note: This product is required to plug into its own
dedicated circuit, rated at the controller’s required
voltage and amperage.
Note: This product is for use with manual pumps only.
A manual pump is a pump that runs when plugged into
an outlet, regardless of the presence of water. Water
sensor(s) are supplied with this unit for pump control.
Safety PrecautionS
WARNING: To prevent re or shock hazard,
do not expose this product to rain or moisture.
This product has a NEMA-1 rated enclosure for use in
an indoor environment. Never spill liquid of any kind
on the product.
DANGER: Risk of electric shock. To reduce
risk of electric shock, do not remove cover.
There are no user-serviceable parts inside. Refer
servicing to qualied service personnel.
DANGER: To prevent electric shock, ensure
product is connected to a grounded outlet.
The electrical outlet should be properly wired to a
dedicated circuit breaker. Proper short-circuit and
overload protection must be provided at the
distribution panel. Install in accordance with all local
and national electrical codes. Recommended
mounting is above oor level. For best performance,
do not use electrical extension cords.
General overview
Thank you for purchasing an Ion Genesis
®
controller.
Take the time to read the instructions carefully before
using this appliance. We strongly recommend that
you keep this instruction manual in a safe place for
future reference.
The Ion Genesis
®
is a residential sump pump controller
for 1 or 2 pumps that includes redundant 72” water
level sensors, a congurable water level/pump turn-
on setting, 2-pump alternation, pump failure sensing,
local audible/visual alarm notication, and optional
remote alarm notication.
Indicators
The front panel has LEDs, a display, and an audible
alarm to offer direct feedback to the user.
Buttons
The front of the controller has buttons labeled
“SILENCE/RESET” and “PUMP TURN ON LEVEL”.
Pressing the SILENCE/RESET button mutes the
audible alarm when an alarm is active. Any future
alarms will activate the audible alarm again.
When held, the SILENCE/RESET button restarts the
controller as if it were unplugged. At start up, the
controller runs pump #1 temporarily, followed by the
second pump, if it exists (as congured in the menu
section).
The PUMP TURN ON LEVEL buttons set the water
level at which the rst pump turns on. It is measured
in inches, up from the middle of the lower water
sensor (see the Installation section). When the water
level is pumped down to the middle of the lower water
sensor, the pump is turned off. This setting only
pertains to the lower water sensor.
inStallation
NOTE: IF YOU ARE INSTALLING THE GENESIS
TO AN EXISTING SUMPRO MODEL 75, PLEASE
CONTACT MANUFACTURER FIRST.
1. See Figure 1, Page 2. Clamp the two water
sensors to any riser pipes in the basin, one
water sensor above the other, with one near
the bottom of the pit and one above the Pump