Switch Manual

Ion
®
Digital Level Control
Digital Level Control Switch
OPERATION MANUAL
Dated: 08/01/2017
Document Name: IonDigitalLevelControl_OM
Page 2 of 4
www.ionproducts.net
SAFETY PRECAUTIONS
CAUTION: To prevent electric shock, ensure
product is connected to a grounded outlet.
The electrical outlet should be properly wired to a
dedicated 15A circuit breaker. Proper short-circuit
and overload protection must be provided at the
distribution panel. Install in accordance with all local
and national electrical codes.
WARNING: Electrical outlet must not be
located in pump pit. For best performance, do
not use electrical extension cords.
INSTALLATION DRAWING
Lowest
pump
off level
BE SURE TO MOUNT THE ION
SWITCH AT PROPER LEVEL.
Range
of 6”-8.5”
Ion
®
Digital
Level Switch
Recommended
1/8” anti-airlocking
hole (if not already
provided by pump
manufacturer)
or
Optional
bracket
FIGURE A
FIGURE C
5”
Ø 3 7/8”
FIGURE B
FIGURE D
Range
of 6”-8.5”
NOTE: If you purchased a pump with the Ion switch
hard-mounted to the pump (Figure D) and the
installation requires the switch be mounted to the
pipe, the pipe-mount bracket is sold separately, PN:
IN-SPB1-1.
Ion
®
Switch
piggy back
Pump plug
FIGURE E