Digital Level Control
Digital Level Control Switch
SAFETY PRECAUTIONS
CAUTION: To prevent electric shock, ensure
product is connected to a grounded outlet.
The electrical outlet should be properly wired to a
dedicated 15A circuit breaker. Proper short-circuit
and overload protection must be provided at the
distribution panel. Install in accordance with all local
and national electrical codes.
WARNING: Electrical outlet must not be
located in pump pit. For best performance, do
not use electrical extension cords.
INSTALLATION DRAWING
Lowest
pump
o󰀨 level
BE SURE TO MOUNT THE ION
SWITCH AT PROPER LEVEL.
Range
of 6”-8.5”
Ion
®
Digital
Level Switch
Recommended
1/8” anti-airlocking
hole (if not already
provided by pump
manufacturer)
or
Optional
bracket
FIGURE A
FIGURE C
5”
Ø 3 7/8”
FIGURE B
FIGURE D
Range
of 6”-8.5”
NOTE: If you purchased a pump with the Ion switch
hard-mounted to the pump (Figure D) and the
installation requires the switch be mounted to the
pipe, the pipe-mount bracket is sold separately, PN:
IN-SPB1-1.
Ion
®
Switch
piggy back
Pump plug
FIGURE E