INDEX IMPORTANT SAFETY INSTRUCTIONS ..................................................................................1 FEATURES .............................................................................................................................. 2 SPECIFICATIONS..................................................................................................................... 2 PRODUCT DESCRIPTION ...................................................................................................
IMPORTANT SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING. WARNING - This appliance is intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to person or property. When using electrical appliances, basic safety precautions should always be followed: 1. Do not operate the unit with a damaged cord or plug, after it malfunctions or has been dropped or damaged in any way.
FEATURES • Compressor dehumidifier - uses CFC-free R134a refrigerant • Environmentally friendly - no harmful gases and quiet in operation • Moisture removal - 12 litres/day (30°C RH80%) • Water tank capacity - 1.
PRODUCT DESCRIPTION LCD Control panel Air outlet Handle Filter Air inlet Water tank Continuous drainage hole THE CONTROL PANEL Water tank full indicator Power button Dimming indicator Dehumidifying Timer button Timer indicator Displays only when timer is set Displays when LCD backlight is dimmed Defrost indicator Room humidity / Setting indicator Humidity setting indicator Backlight dimming button Relative Humidity button Dehumidifying mode Blinks when defrosting Blinks when water tank is ful
UNIT SETUP Top above 60cm Place the unit in an upright position on a stable, level surface. (Please ensure unit is not sitting on its own cable) Air outlet Air inlet (Back) above 20cm above 50cm ! above 20cm above 20cm Please ensure the unit is a safe distance away from walls and furniture (see image on the left). Please keep clothes at a safe distance of 60cm from air outlet of the unit to prevent water dripping into the unit.
OPERATING INSTRUCTIONS ON and OFF Connect the power plug to the appropriate electrical outlet. Press the ON / OFF button to turn the appliance ON. The LCD panel will light up. If the unit has been switched off and on again, it will resume operation with the settings for mode, humidity and backlight from its last use. Only the timer setting will be reset to zero.
OPERATING INSTRUCTIONS RELATIVE HUMIDITY Press to set your desired humidity level from 40% to 70% RH (at 5% increments) or CO (continuous mode). For example, if 50% RH is selected, the unit will operate and dehumidification will occur when the room humidity level is detected at above 50% RH. After setting the desired humidity level, the indicator and digits on the LCD panel will blink for 5 seconds and then return to display the room humidity level. 40% 45% ...
OPERATING INSTRUCTIONS LCD BACKLIGHT DIMMING Press to change backlight from H (no dimming), L5 (slightly dim) to L1 (dimmest) or L0 (no backlight). The indicator lights up only when the unit has been set between L0 and L5. H (no dimming) L5 (slightly dim) L0 ... L1 (dimmest) (no backlight) AUTO PAUSE AND RESTART FUNCTION Once the desired humidity level is reached, the unit will pause dehumidification for 60 minutes (LCD panel will display “ ”).
EMPTYING THE WATER TANK 1. When the water tank is full, the indicator light blinks and the unit will stop operating. 2. Do not move the unit or remove the water tank if the machine is still operating as water may leak, damage the unit or cause an electric shock. 3. To remove the water tank, pull it out by gripping the sides of the water tank and lifting it carefully. 4. Pour the water away, clean the water tank and install the water tank back into the unit.
CONTINUOUS DRAINAGE OPTION A hose with an inner diameter of 12mm can be connected for continuous drainage: Knockout Hose 1. Use a screwdriver to remove the knockout at the back (on the tank). Attach the hose to the connector through the hole. 2. The hose must lead to an appropriate drain at a downward slope with no sharp bends. Note: 1. Ensure the water tank is well fitted in position before inserting the hose. 2. Before removing the water tank, ensure the hose is disconnected.
MAINTENANCE Cleaning the unit 1. Turn off the unit, wait for the fan to stop and unplug from the electrical outlet. 2. Clean the casing using a soft damp cloth with warm water and mild detergent. Do not use solvents or abrasive materials. 3. Dry thoroughly with a soft dry cloth after cleaning. 4. In order to avoid damage, do not wash the machine with water or let water drip into the air inlet or outlet.
TROUBLESHOOTING The following conditions are normal: 1. The compressor will stop or rest for 3 minutes every time the unit shuts down or is plugged in to the electrical outlet. This helps ensure a smooth start for the dehumidifier. 2. The unit works within room temperature of about 5 ~ 35ºC. It may stop operation when the room temperature is out of this range or when the air inlet or outlet is covered. 3. The unit could increase the room temperature by 1 ~ 3ºC.
12
WARRANTY REGISTRATION Register your Ionmax Ion622 online at my.andatech.com.au Alternatively, fill out this form and forward to the address below with a copy of your proof of purchase. Andatech Pty Ltd PO Box 3038, Nunawading VIC 3131, Australia. Product : Ionmax Ion622 Date of Purchase : ____________________________________ Place of Purchase : ____________________________________ Serial No.