Appendix F: Inspection of Equipment for Return to Service
1. Enclosure base and lid shall be free of cracks.
2. O-ring shall be free of cracks. If any part of the o-ring is removed, the o-ring gland must be
cleaned to be free of particulates.
3. Clean top edge of enclosure base and o-ring surface with damp cloth.
4. Clean enclosure lid o-ring bump-out with damp cloth.
5. Inspect power wires. Insulation shall be free of cracks.
6 Inspect NFC antenna and wire. Both shall be free of cracks
7 Inspect circular Gore vent under enclosure base. Gore vent shall show no evidence of
peeling, puncture, or cracking.
8 E6X version only: Inspect coax cable and antenna. Both shall be free of cracks.