I9-2000W/N UHF RFID Reader User Manual Copyright ® ioTware co., LTD. All rights reserved ISSUE DATE : 2021.08.09 The pictures and screens shots on this document may be different to actual. . Please thoroughly read the caution section before installing the reader. Reasonable measures have been taken to ensure that the information included in this manual is complete and accurate. However, UBISTS reserves the right to change any specification at any time without prior notice.
Contents CONTENTS ................................................................................................................................................ 2 CHAPTER 1. INTRODUCTION .......................................................................................................... 4 1.1 OPERATION SPECIFICATION ............................................................................................................... 4 1.2 COMMUNICATION SPECIFICATION ........................................
FCC information FCC notice "Declaration of Conformity Information" This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. 2021-08-05 - 4 of 30- ioTware Co., Ltd.
Chapter 1. Introduction 1.1 Operation specification I9-2000W supports multi-protocols (ISO18000-6C&6B, EPC Class 1 GEN 2) to read and write tags. I9-2000W supports RS-232 and TCP/IP. I9-2000W supports external I/O and controls other devices through the digital I/O. Easy to monitor the status of reader through LED. Easy to control the reader through the reader’s API. I9-2000W provides online upgrade. Preferable mode can be saved by the user.
1.3 Reader specification Item Model name Air interface protocols Specification Remark I9-2000W/N ISO-18000-6B/6C, EPC Class1 Gen 2 910.4~913.6 MHz@Korea/ MIC ETSI(EU) 917.3~920.3MHz@Korea/ KCC Frequency range 902.75~929.25 MHz@USA/ FCC 865.7~867.5 MHz@EU/ CE 952.4~953.6 MHz@Japan/ TELEC 920.625~924.
LBT control Power supply voltage DC Current Weight Dimensions Supports sensitivity setting DC 12V (±10%) MAX 3000mA 3.5kg 169 x 88 x 47 (mm) Connector:RJ45, LAN Standard : IEEE802.3, 10Base T Protocol: TCP/IP Serial Extended I/O 2021-08-05 RS-232C, Baud Rate : Max 230,400bps 4 Inputs and 4 outputs - 7 of 30- ioTware Co., Ltd.
1.4 Product images I9-2000W/N reader (Top view, front view) TopView FrontView 2021-08-05 - 8 of 30- ioTware Co., Ltd.
Chapter 2. Hardware Installation 2.1 Hardware 2.1.1 Reader I/O Panel DC12V EXT I/O 1 EXT I/O 2 RS-232 LAN ANT1 ANT2 ANT3 ANT4 Power Table 1] 입력전원 요구 사항 Input voltage DC 12V (±10%) Input Cur 3000mA more than Ripple and ripple noise 50mVp-p or less Spike at the moment: 100mVp-p or less Power Connector (DC Power Socket & Jack) 2021-08-05 - 9 of 30- ioTware Co., Ltd.
Antenna Port Antenna Connector RF specification Item Specification Remark 910.4~913.6 MHz@Korea/ MIC 917.3~920.3MHz@Korea/ KCC Frequency 902.75~929.25 MHz@USA/ FCC Range 865.7~867.5 MHz@EU/ CE 952.4~953.6 MHz@Japan/ TELEC 920.625~924.
Antenna Gain 6dBi Below 17 Channels @Korea/ MIC 6 Channels @Korea/ KCC 50 Channels @USA/ FCC Channels 4 Channels @EU/CE 8 Channels @Japan/ TELEC 16 Channels@China/ CC 200KHz@Korea/ MIC 600KHz @Korea/ KCC Channel Band 500KHz @USA/ FCC Width 600Khz @EU/CE 200KHz @Japan/ TELEC 250KHz @China/ CE 2.1.2 LED Panel POWER (Red): It indicates the power; ON/OFF READ (dual color): It flashes when the reader reads the tags. 2.2 Hardware installation ① Locate the host PC.
Chapter 3. Software Installation 3.1 Check before installation ① Confirm the appropriate software. ② Confirm the host PC that connects to the network. 3.2 Software installation ① Copy the software into the host PC (E.g.. Copy the U9-2000 folder onto D:) Software Folder ※ Firmware folder: It includes .bin file in order to upgrade a firmware. Register file folder: It includes .rgs file in order to set a registry RfBag.exe: It is the executable PC program. 2021-08-05 - 12 of 30- ioTware Co., Ltd.
② When you execute the RfBag.exe, you can see the Main Menu window as follows. Main Window after excuting RFIDDEMO 2021-08-05 - 13 of 30- ioTware Co., Ltd.
Chapter 4. Software Operation There are two ways to operate the U9-2000N UHF Reader. One is to operate the reader with directly received input and the other is the Machine-to-Machine(MtoM) mode, in other words, to operate automatically by the connected host or software which has been programmed in the middleware. In order to operate in MtoM mode, you need the program that is developed with the appropriate protocol which is discussed in chapter 6 and 7.
String Protocol Mode methods in the transition to Binary Protocol String Protocol "SerialMode" command is listed in detail. ① Connect the RS232C cable to the reader. ② In the Main Menu, choose the Option from Help or configuration button, the Configuration window opens. ③ Choose the Serial from Communication Type. ④ Select the host PC’s communication port. (ex. COM1, COM2….
Information of Internal Message 4.3 Search the reader using the program and Ethernet ① Connect the Ethernet cable to the reader. ② Either select the Search Reader from the Function or Scan button to search the reader. Reader Search Screen 2021-08-05 - 16 of 30- ioTware Co., Ltd.
③ Click a Scan Reader button. ④ The information about thea reader on the local network area will appear. Search the Reader's info 4.4 Connect the host PC and reader through the Ethernet ① Connect the reader and host PC using the Ethernet Cable (Cross Cable). If you have multiple readers, use the Ethernet Network Hub to connect with the PC. ② From the Main Menu, select Help → Option or configuration button. The Configuration window appears.
⑤ From the main window, click the Connect button to connect the reader and the host PC. ⑥ To check the connectivity between the reader and the host PC, click the Info button. ※ How to check the IP Address of the reader 1. Connect the reader and the host PC through the RS232. 2. From the main window, click the reader button. The Reader Config Command window appears. 3. Click the RN(Read Net) button from the Reader Network to see the IP Address, Subnet Mask, Default Gateway and DNS Address.
Reader Config Command Window of the Reader Network 2021-08-05 - 19 of 30- ioTware Co., Ltd.
4.5 Check or change the register settings You can view the value of the Register using the HR(HardwareRead) button. And also you can modify the value using the HS(HardwareSetup) button. ① Connect the reader and the host PC, click Register button. The Register Read/Write window appears. . Register Read/Write Window ② 2021-08-05 To check the default value of the Register, click HR(Hardware Read). - 20 of 30- ioTware Co., Ltd.
※ If the HS or HR are deactivated, check the connectivity between the reader and the host PC. ③ Check the check box to modify the value of the Register. Register Time Slot Change the value of the RF Attenuator ④ Click the HS(HardwareSetup) button to apply the changed value. ⑤ To check the modified value, click HR(HardwareRead) button. ※ If you want to have more information on the Register, please see the chapter6 for the Binary protocols. 2021-08-05 - 21 of 30- ioTware Co., Ltd.
※ How to keep the current setting as the default register value ① The default register value is saved on the flash memory. ② You can change the default register setting using the SR Command. ③ From the Main Menu, click the Register button. The Register Read/Write window appears. ④ Click the HR(HardwareRead) to view the current register value. Ant the click the Save Register button.
4.6 How to read tags while using the single port ※Tag caveat before reading 1. [Chapter 2] Hardware Installation Connect the Reader to read and make sure that appropriate. 2. Reader supported on this machine is ready to make sure that the Tag. 3. Tag Reader to read well and where you can make sure that you have placed in fr ont of the Ant. ① You need to set the Register value in the reader to read the tag. ② Click the Register button from the Main Menu, the Register Read/Write window appears.
Command Window1 (Tag) of the AC (Anti Collision) ⑦ Click 1 Port Notify Start button ※ from the AC(Anti Collision) to read tags. To view the raw data view, click Raw button from the Main Menu. The Serial Raw Data View window appears. From this window, you can see the [Send Data] from the reader to the host PC and the [Receive Data] for their responses. ※ Use this view to check other commands. ⑧ 2021-08-05 The tag data is displayed.
number and the tag reading time. 메인 Window 에서 Tag UID 확인 ⑨ In order to stop the transmission Tag Command Window1 (Tag) of the AC (Anti Collision) from the Clicking Tag transfer is complete. 2021-08-05 - 25 of 30- ioTware Co., Ltd.
4.7 How to change antenna setting while using a Single Port ① Connect the reader and the host PC. ② Check the current port. Check the current Port(ANT1) ③ Change the antenna cable from ANT1 to ANT2. Port 1 and Port 2 as a replacement ④ Click the Register button from the Main Menu. ⑤ Select the 05h:Cur. Antenna and choose 2 for the antenna port 2. Click HS(HardwareSetup) button to save the changes.
Window to verify the result f a change through the main antenna 2021-08-05 - 27 of 30- ioTware Co., Ltd.
4.8 How to read tags while using multiple ports ① Connects the reader with more than 2 antennas. Reader Connect the two antenna ② Connect the reader and the host PC, click Resister button. Register Read/Write window appears. ③ Select 10h:MAX Antenna and choose 2. Click HS(HardwareSetup) to save the changes. ④ From the Main Menu, click the Tagcmd button to open the Command window1 (Tag). Click 1 Port Notify Start button.
Check the results through the Multi Port Main Window ※ Tag Multi Port while reading only the specific antenna Register Read / Write Window at 05h: Cur.Antenna antenna set to receive the part after Tag Command Window1 (Ta g) Window of the AC (Anti Collision) If you click on the button Tag can be read only on a specific antenna. 2021-08-05 - 29 of 30- ioTware Co., Ltd.
4.9. Tag Read Test ① From the Main Menu, click the Test button. The Tag Read Test window appears. Tag Read Test Window ② Select the 1Port Notify Start and set the time for tag reading test. Click Start button. ③ The Stop button stops the test. ※ Auto Clear Option: Before the test, delete the tag data from the Main Menu automatically. ▪ Clear Tag Data: Delete the all tag data from the Main Menu.