Iota Charger Ratings

DLS RATINGS AND SPECIFICATIONS
REV 042412
IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com
13.6V (DC)
+ or - .7%
15 Amps
>13.4V (DC)
200 Watts
<50 mV rms
108 - 132 AC
47-63
3.7 Amps
>80%
30 Amps
Ye s
>100%
100 mV rms
<1%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7 x 6.7 x 3.4
5.0 lbs
DC Output Voltage (No Load) approx.
Output Voltage Tolerance (No Load)
Output Amperage, Max Continuous
Output Voltage (Full Load) approx.
Maximum Power Output, Continuous
Ripple and Noise
Input Voltage Range
Input Voltage Frequency
Maximum AC Current (@108Vac)
Typical Efficiency
Max Inrush Current, Single Cycle
Short Circuit Protection
Overload Protection
Line Regulation
Load Regulation
Fan Control
Thermal Protection
Working Temperature Range
Storage Temperature
Withstand Voltage (VDC)
Approximate Dimensions
Weight
13.6V (DC)
+ or - .7%
30 Amps
>13.4V (DC)
400 Watts
<50 mV rms
108 - 132 AC
47-63
7.3 Amps
>80%
30 Amps
Ye s
>100%
100 mV rms
<1%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7 x 6.7 x 3.4
5.0 lbs
13.6V (DC)
+ or - .7%
45 Amps
>13.4V (DC)
600 Watts
<50 mV rms
108 - 132 AC
47-63
11 Amps
>80%
30 Amps
Ye s
>100%
100 mV rms
<1.5%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7 x 6.7 x 3.4
5.0 lbs
13.6V (DC)
+ or - .7%
55 Amps
>13.4V (DC)
750 Watts
<50 mV rms
108 - 132 AC
47-63
13.4 Amps
>80%
30 Amps
Ye s
>100%
100 mV rms
<1.5%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7 x 6.7 x 3.4
5.0 lbs
13.6V (DC)
+ or - .7%
75 Amps
>13.4V (DC)
1000 Watts
<100 mV rms
108 - 132 AC
47-63
18.2 Amps
>80%
40 Amps
Ye s
>100%
100 mV rms
<1.5%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
13 x 6.5 x 3.4
7.8 lbs
DLS-15 DLS-30 DLS-45 DLS-55 DLS-75
**Requires 30A breaker
SERIES M SERIES M SERIES M
DLS 90 *
13.6V (DC)
+ or - .7%
90 Amps
>13.4V (DC)
1200 Watts
<150 mV rms
108 - 132 AC
47-63
21.8 Amps**
>80%
40 Amps
Ye s
>100%
100 mV rms
<1.5%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
13 x 6.5 x 3.4
7.8 lbs
SERIES M
RATINGS AND SPECIFICATIONS
Primary to Chassis/Primary to Secondary/Secondary to Chassis
IOTA DLS converter/chargers are supplied with a
power cord (approx. 36 inch length) for connection
to the AC input. Plug type on the cord is determined
by the input voltage and ratings of the DLS model
and/or UL specifications.
CORD CONFIGURATION
DLS-15
DLS-30
DLS-45
DLS-55
DLS-75
DLS-90
12-VOLT DLS
CONVERTERS/CHARGERS
*Unit is not UL Listed