2.4 nano3G S8 AP Site Requirements
In addition to the site requirements for all APs, each S8 AP will require:
Power supplied in one of the following ways, according to the accessory unit(s)
supplied with the S8 AP:
From the mains adaptor unit, which requires a suitable mains power supply
point near the AP that is within reach of the adaptor’s cabling
or
From the supplied POE splitter, which requires a Power over Ethernet
connection to the splitter
A site for the AP:
Wall mount location
or
Stable surface for free standing installation
2.4.1 nano3G S8 AP Power Requirements
Maximum expected power consumption:
13 Watts (Rated 9VDC 1450mA)
The nano3G S8 AP supports the following power and Ethernet cabling options:
Direct power from the power adapter
Power over Ethernet from the POE injector, via the POE splitter
Power over Ethernet from a POE switch, via the POE splitter
A POE cable must not be inserted directly into the AP.
The power adapter, as well as the POE inserter and splitter supplied by ip.access comply
with LPS requirements in accordance with IEC/EN 60950-1.