Installation Instructions
Table Of Contents
- nano3G AP Installation Manual
- Table of Contents
 - 1 Introduction
 - 2 Installation Overview and Requirements
 - 3 Pre-Provisioning a nano3G AP
 - 4 Configuration File Preparation
 - 5 Commission a nano3G AP
 - 6 nano3G AP Hardware Installation
 - 7 Finalize Installation
 - 8 Troubleshooting
 - 9 nano3G AP and PSU Regulatory Information
 
 
nano3G AP Installation Manual Installation Overview and Requirements
N3G_INST_300 v8.1 for N3G_2.0.5 © ip.access Limited 2011 Page 16
POE+ Injector
The POE+ injector unit is supplied as standard with each nano3G E8 AP. The POE+ 
injector has two Ethernet connections, one for connection to the main LAN, the other for 
connection to the AP. The POE+ injector can be located anywhere on the cable run 
between the network switch and the AP, including locally at the AP or remotely at the 
network switch.
The POE+ injector is a pass-through connector for the LAN. Its function is to add POE+ to 
provide power to the AP. Therefore, the maximum cable run from the network switch to the 
AP is 100m, regardless of the placement of the POE+ injector.
The POE+ injector supplied by ip.access complies with LPS requirements in accordance 
with IEC/EN 60950-1.
2.5.2 nano3G E8 AP Physical Requirements
A nano3G E8 AP is installed by attaching it to a wall or partition using the two screws which 
engage in keyhole slots in the rear surface of the AP (see section 6.4.6).
Pay attention to ensure that air can circulate freely around the unit. The unit must be 
vertical.
It is recommended to install the AP with its front surface facing the area requiring cellular 
coverage, unobstructed by walls or partitions that may have significant RF attenuation.
Dimensions and 
weight
Height 211mm
Width 274mm
Depth 58.6mm
Approximate Weight 1.75 kg
Environmental Cooling Vents on the back at top and bottom
Operating Temperature 0°C to +45°C
Operating Humidity 10 to 70% non-condensing