Installation Instructions
Table Of Contents
- nano3G AP Installation Manual
- Table of Contents
 - 1 Introduction
 - 2 Installation Overview and Requirements
 - 3 Pre-Provisioning a nano3G AP
 - 4 Configuration File Preparation
 - 5 Commission a nano3G AP
 - 6 nano3G AP Hardware Installation
 - 7 Finalize Installation
 - 8 Troubleshooting
 - 9 nano3G AP and PSU Regulatory Information
 
 
nano3G AP Installation Manual nano3G AP Hardware Installation
N3G_INST_300 v8.1 for N3G_2.0.5 © ip.access Limited 2011 Page 58
6.4.6 Mount the nano3G E8 AP on a Wall
Note: The nano3G E8 AP should be installed in a position so that it is at least 2m away from the 
area where handsets are normally used.
The nano3G E8 AP must be mounted vertically to ensure air circulation around the unit.
The location of each nano3G E8 AP is shown on the installation floor plan produced at the 
network planning stage. For example, it must take into account that all APs must be at least 
2m from any mobile equipment. The network wiring must be complete before the nano3G 
E8 AP can be installed and commissioned. The nano3G E8 AP should be placed on a wall 
at or above head height.
1) Remove the nano3G E8 AP from the wall bracket. Lay the AP on a flat surface with 
the wall bracket upwards. Slide the removal tool over the central fin between the 
bracket and the body of the unit to disengage the locking spring, then slide the 
bracket to separate it from the AP. The removal tool may be inserted from the top 
or bottom of the nano3G E8 AP.