nano3G AP Installation Manual Installation Overview and Requirements
N3G_INST_300 v292_1.0 for N3G_2.92 © ip.access Limited 2012 Page 26
Only use the POE splitter available from ip.access:
2.4.2 nano3G S16 AP Physical Requirements
A nano3G S16 AP may be installed in one of the following ways (see section 6.2.4):
Free-standing on a flat stable surface.
Attached to a wall or partition using two screws that engage in keyhole slots in the
rear surface of the AP.
Attached to a POE splitter using the two screws that engage in keyhole slots in the
rear surface of the AP. The POE splitter in turn attaches to a wall or partition using
two screws.
The unit must be vertical to ensure that air can circulate freely around it.
It is recommended to install the AP with its front surface facing the area requiring cellular
coverage, unobstructed by walls or partitions that may cause significant RF attenuation.
ip.access part number 222A
Input 48VDC 0.35A
Output 9VDC 1.33A
Dimensions and
weight
Height 176mm (without stand)
193mm (with stand)
Width 170mm
Depth 51mm
Approximate Weight 0.42 kg (AP only)
Environmental Cooling Vents on the back at top and bottom
Operating Temperature 0°C to 40°C
Operating Humidity 10 to 70% non-condensing