User's Manual
Table Of Contents
- nano3G AP Installation Manual
- Table of Contents
- 1 Introduction
- 2 Installation Overview and Requirements
- 2.1 Installation Tasks
- 2.2 Requirements for All nano3G APs
- 2.2.1 General Requirements
- 2.2.2 nano3G AP Cooling
- 2.2.3 Information Required for Pre-Provisioning
- 2.2.4 Parameters for Enterprise Deployments
- 2.2.5 Parameters for Residential Deployments
- 2.2.6 Access Control
- 2.2.7 Closed Access with CSG Parameter Broadcast
- 2.2.8 Closed Access in Legacy Mode
- 2.2.9 Pre-Prepared Configurations - Optional
- 2.2.10 Information Required for Commissioning
- 2.2.11 Other Items for Commissioning
- 2.3 nano3G S8 AP Site Requirements
- 2.4 nano3G S16 AP Site Requirements
- 2.5 nano3G E8 AP and nano3G E16 AP Site Requirements
- 3 Pre-Provisioning a nano3G AP
- 4 Configuration File Preparation
- 5 Commission a nano3G AP
- 6 nano3G AP Hardware Installation
- 7 Finalize Installation
- 8 Troubleshooting
- 9 nano3G AP and PSU Regulatory Information
nano3G AP Installation Manual Commission a nano3G AP
N3G_INST_300 v292_1.0 for N3G_2.92 © ip.access Limited 2012 Page 54
9) Wait about a minute for the download to take place.
10) To restart the AP from the new software just downloaded, briefly press the reset
button.
11) Once the AP has started, repeat the factory reset by holding down the reset button
for at least 5 seconds. When the AP restarts this time, refresh the browser to
access the login prompt and login again with the commissioning user name and
password.
12) Click the SW Download link on the left.
13) Inspect the software version information to verify that the AP has booted from the
downloaded software.
14) To ensure the standby bank also has the latest software version, repeat the
software download, but do not restart the AP. It is not necessary to restart the AP
once it is already running the updated software.
This ensures the AP does not have old software on the standby bank. Hence, if the
AP is commanded to switch banks, it will run up-to-date software.
5.4.2 ATAS Check and Download
This is only required if the AP needs an additional ATAS package that is not already factory
installed. For example, if the AP will use IPsec and the security gateway certificates are not
supplied by ip.access Limited.
Use the ATAS Download page to check the current ATAS package. If necessary, also
download a package of trust anchors that are appropriate for the AP’s target network.
ALERT: The ATAS package on the AP must be correct according to the IPsec security gateway
(SecGW) that will terminate the IPsec connection for the AP. If the ATAS package is
incorrect, the AP will not connect to the SecGW and hence will be unable to enter service.