8.3.3 nano3G E8 AP and nano3G E16 AP Factory Reset
1) Use a thin rod to press and hold the reset button.
2) Keep the reset button pressed until the 3G LED changes from blinking fast (50ms
on, 50ms off) to blinking slowly (200ms on, 200ms off).
The 3G LED blinks fast (50ms on, 50ms off) until the factory reset commences,
then it blinks slowly (200ms on, 200ms off). When the factory restore process is
complete, the LED extinguishes and the AP automatically reboots, takes the fixed
IP address and enables the web interface for commissioning.
3) If required, use a connected commissioning terminal to login to the AP’s web
interface. The login to the web interface is only available for 60 seconds. If the AP
times out, it will boot up using the default set of parameters, as per the current
entries on the commissioning web page.