3.5.5 Network Interfaces
The AP provides a single electrical Ethernet network interface via a standard RJ45 socket.
The interface supports 1Gbps with MDI/MDIX cable auto-selection.
The Ethernet interface is used for:
Backhaul connection to the EPC via S1 over IP
OA&M connection to NOS via TR-069
This interface is IP access medium (e.g. DSL or LAN) agnostic subject to the bandwidth,
jitter and latency being within limits.
The backhaul and management connections are secured using IPsec.
3.5.6 Reset Button Description
The nanoLTE E40 AP has an internal reset button to allow manual rebooting of the unit.
Press for up to 5 seconds (subject to change) to execute a soft reboot of the AP
Press for more than 5 seconds to execute a restore to factory defaults
The reset button is not exposed on the external enclosure. However, as it is recessed with
respect to the external casing and is accessible via a small hole, it can be operated by
means of a simple mechanical reset tool, such as a needle.
3.5.7 Visual Indicators
The nanoLTE E Class AP has the following LED indicators that display the status of AP:
•4G Power
Red at power up then Green when initialisation is complete
•4G Service
A red/green LED that shows the services status of the AP - steady green
indicates normal service, while other states can indicate firmware upgrade in
progress, provisioning states and certain fault conditions
Ethernet - The Ethernet port has integrated LED indicators showing connection
status and link activity
3.5.8 Environmental Conditions
The AP complies with the environmental conditions set out in EN 300 019.
The nanoLTE E40 AP has an ingress rating of IP40 in accordance with EN 60529 and is
cooled passively (i.e. no internal fan).
Temperature Humidity
Operating Conditions 0C to +40C 10% to 70% non-condensing