Installation Instructions

nanoLTE S60 AP Hardware Installation Installation Overview and Requirements
NANO_INST_43315 v200_0.5 for N4G_2.0 © ip.access Limited 2017 Page 7
2.3.5 S60 AP Physical Requirements
An S60 AP is installed by mounting it on a wall or partition on screws or by sitting it on the
supplied stand.
Pay attention to ensure that air can circulate freely around the unit. The unit must be
vertical.
It is recommended to install the AP with its front surface facing the area requiring cellular
coverage, unobstructed by walls or partitions that may cause significant RF attenuation.
2.3.6 Thermal Protection
The nanoLTE S60 AP may become warm during normal operation.
Ensure the AP is in a location where it will be at least 20cm away from personnel and any
items that may be heat sensitive.
2.3.7 S60 AP Backhaul (IP) Bandwidth Requirements
At maximum capacity and with IPsec in use, a nanoLTE S60 AP will require:
Downlink: 150Mbps
Uplink: 50Mbps
This will provide bandwidth for 32 users.
2.3.8 S60 AP Installation Tool Requirements for Wall Mounting
To mount the S60 on a wall:
2 pan head screws, size No. 6 (approx 3.5mm (0.14in) in diameter).
Wall plugs if required.
Suitable drills and screwdriver.
None of these items are included in the box with the S60 AP.
Dimensions and weight
without stand
Height 130mm
Width 176mm
Depth 34mm
Approximate Weight 360g
Dimensions and weight with
stand
Height 137mm
Width 188mm
Depth 46mm
Approximate Weight 385g
Environmental Cooling Vents on the top and bottom
Operating Temperature 0°C to +45°C
Operating Humidity 10 to 70% non-condensing