Installation Instructions

© ip.access Ltd
COMPANY CONFIDENTIAL 110#010XA_GDE.doc
- 10 -
Ruler dimensioned in mm.
T20 Torx screwdriver required if external antenna kit is used
Configuration:
Frequency counter with 12-digit display with a reference oscillator stability better
than 10
-9
.
If the reference nanoBTS adjustment is to be performed manually, then an
isolated 10-way RJ45 to BNC lead is required.
Laptop PC preinstalled with the ip.access “nanoInstaller” and associated
configuration files.
Walk Test:
A test mobile or other GSM measuring device.
.
Installation Steps
1. Unpack nanoBTS
2. Install PSUs
3. Fix mounting brackets
4. Modify nanoBTS for external antennas (if required)
5. Attach nanoBTS to mounting bracket
6. Record nanoBTS MAC address and location.
Configuration Steps
1. Set up PC for configuring nanoBTS
2. Connect the nanoBTS
3. Set IP address and optionally download operational software
4. Set frequency of nanoBTS oscillator
5. Calibrate the nanoBTS using frequency synchronisation
6. Check macro network channel usage
7. Retrieve BCCH frequency information
8. Measure path loss between nanoBTS sites
9. Walk Test
10. Installation Report
Unpacking nanoBTS
Unpack nanoBTS and check to see that the unit has not been damaged in transit. Any
damaged units should be returned to your supplier.