User's Manual

CHAPTER 5: PROGRAMMING INSTRUCTIONS
©2005 IMobileNet, Inc. Revision & Copyright HSBS User Manual
516.80540.UM-Rev. D 1-Jun-07 Page 25 of 38
Step 7 At the COM Properties window make sure the properties selected are as follows:
B
its per second: 9600
Data bits: 8
P
arity: None
S
top bits: 1
Flow control: None
Step 8 Click on the OK button.
Step 9 Open HyperTerminal.
Step 10 Recycle the base power and HyperTerminal displays the base’s Firmware revision.
Step 11 Type in a ? in the HyperTerminal screen and press [ENTER]. This will list the Base
Station parameters, as shown in the sample below. If the cursor is not responsive, check
the cables for proper connection.
S Ensure that the calibrated base station and the mobile radio antennae are separated by
at least 10 feet. If the antennae are too close, the mobile radio receivers are overloaded
by the transmitters resulting in intermittent communication and high data errors.