User's Manual

APPENDIX B: BASE STATION PARAMETERS
©2005 IMobileNet, Inc. Revision & Copyright HSBS User Manual
516.80540.UM-Rev. D 1-Jun-07 Page 31 of 38
BASE STATION PARAMETERS
PARAMETER DESCRIPTION / VALID VALUES DEFAULT
host interface
Valid Values:
ethernet, status/no status; slip, status/no status
ETHERNET, status
host serial
Sets the baud rate o the serial connection. “Timeout”
specifies, in milliseconds, the time to end the frame if
the end of frame character is not received.
Valid Values:
Baud, parity, data bits, stop bits, timeout=xxx
Baud: 9600/19200/38400/57600/115200; Parity: N,
O, E (None, Odd, or Even); Data bits: 7, 9; Stop bits:
1, 2
115200, n, 8, 1,
200
IPNC Valid Values: xxx.xxx.xxx.xxx (xxx=0 to 255) 172.16.23.191
IPNC query period Valid Values: 0 to 32767 (unit in seconds) 0
Model Base station model name. B64850D25
Modem FEC Valid Values: On/Off On
MTU
Used to set the MTU (maximum transmission unit).
Where “n” is the desired mtu decimal value, 1500
maximum. Unlock the base prior to changing this
parameter. The parameter change takes effect
immediately. When the base receives a packet with a
sizer greater than the set mtu, it returns an ICMP
packet (type=3, code=4) to the source. The original
received packet is discarded.
Recommended Values: 576/1500
1500
noise Show noise floor in dBm for each Receiver.
num timeslots Valid Values: 1 to 64 20
polarity Valid Values: RX+, RX-, TX+, TX- RX+, TX-
reference frequency Valid Values: 1 to 100 MHz 16.800000 MHz
rf ip address
Base station’s virtual hardware IP address. Set this to
an available IP address that is within the IPNC’s
network.
Valid Values: xxx.xxx.xxx.xxx (xxx = 0 TO 255)
192.168.3.1