User's Manual

APPENDIX B: BASE STATION PARAMETERS
©2005 IMobileNet, Inc. Revision & Copyright HSBS User Manual
516.80540.UM-Rev. D 1-Jun-07 Page 32 of 38
BASE STATION PARAMETERS
PARAMETER DESCRIPTION / VALID VALUES DEFAULT
rssi step Valid Values: 1 to 255 25
RX in progress
message
Enable/disables receiving packet look-ahead, where “x”
is either 1 or 0 (1=enable; 0=disable). Use to
enable/disable the “receiving packet look ahead
feature. If enabled, as soon as the base receives a
packet header, it sends a short packet to inform the
IPNC of the length, source, address, and arrival time of
the packet being received. IPNC Scheduler uses this
information to decide the appropriate time to send the
next packet to the mobile radio. Unlock base before
changing. The parameter change is effective
immediately.
Valid Values: 0/1 (when set, packets cannot be sent
because the mobile is busy will be returned to IPNC)
1
serial number
Valid Values:
xxxxxx (x is an alphanumeric character, maximum 20)
undefined
sntp interval Valid Values: 0 to 3600 (unit in seconds) 60
station ID
Valid Values: xxxxxxx (x is any alphanumeric character,
maximum of 11 characters)
ABC123
station id time
Valid Values: 0 to 3600 (units in seconds)
0 = OFF
0
symbol sync time
Length of time that synchronization is transmitted
before data is sent and is otherwise known as “TX Sync
Time”.
12
TFTP options
Valid Values: size, t (size=128/256/512 bytes, t=0 to 10
seconds) “T” specified delay in time in ms between
each block
256, 3
time
Base station’s concept of current time, NTP calibration
value
timeslot period Valid Values: 1 to 1000 1000
timeslots per voice
packet
Valid Values: 1 to 16 4