Installation Instructions

APPENDIX B: IPM4 TEST DATA SHEET
IPM4-FCCRpt.doc Page 22
Program and Configure Radio
Date
Serial Number
Firmware Revision
Tester
Adjustment / Alignment Procedures
Receiver Injection
Parameter
Spec
Measured
Injection Frequency Error at RXINJ1(within +/- 100
Hz of exact injection frequency)
+/- 100 Hz
U34 pin 4 power level
-3 to -5 dBm
Receiver 1& 2
Parameter
Spec
Receiver 1
Measured
Receiver 2
Measured
Audio DC Amplitude
(1 kHz Test tone @ 5.0 kHz
Deviation)
2.5 VDC
+/- 1mV
Audio AC Amplitude
(1 kHz Test tone @ 5.0 kHz
Deviation)
350 mVRMS
+/- 1mV
Distortion
(1 kHz Test tone @ 5.0 kHz
Deviation)
3%<
SINAD 12 dB
(1 kHz Test tone @ 5.0 kHz
Deviation)
-118dBm >