2003 IPMobileNet, Inc. 28 IPSeries MR User Manual / Rev. A / 08-Apr-03
Measuring Insertion Loss
To measure Insertion Loss of an unterminated length of coax, perform the following steps:
Step 1 Connect the antenna to be tested to the appropriate Antenna Analyst.
Step 2 Turn on the Antenna Analyst and the Return Loss is displayed in dB to the left of the
VSWR curve.
To switch from the RETL mode to VSWR mode, refer back to the previous set of
instructions.
Step 3 Divide the result by two (2).
Voice Interface Unit Connections
If connecting a VIU, an additional 10-ft serial cable is required (IPMN p/n: 156-0245-010 included with
VIU).
To connect the serial cables, perform the following steps:
Step 1 Attach 20-ft serial cable male connector (DB9M) to the mobile radio.
Step 2 Route the female connector (DB9F) to the driver compartment and connect to the
serial port located on the rear of the VIU near the microphone hang up clip.
Step 3 Attach the 10-foot serial cable male connector (DB9M) to the other serial port
located on the rear of the VIU.
Step 4 Route the female connector (DB9F) serial cable to the serial port located on the rear
of the mobile computer.