mac

Commands for EFM OAM
150
Command Mode: Port mode
Default: 1s.
Usage Guide: Use this command to configure the transmission interval of Information
OAMPDU which keep OAM connection normally.
Example: Set the transmission interval of Information OAMPDU for ethernet 1/4 to be
2s.
Switch(Config-If-Ethernet1/4)# ethernet-oam period 2
10.22 ethernet-oam remote-failure
Command: ethernet-oam remote-failure
no ethernet-oam remote-failure
Function: Enable remote failure indication of OAM, no command disables the function.
Parameters: None.
Command Mode: Port mode
Default: Enable.
Usage Guide: With remote failure indication is enabled, if critical-event or link fault event
is occurred locally, it will notify the peer by sending Information OAMPDU, log the fault
information and send SNMP trap warning. When the remote failure indication is disabled,
although local critical-event or link fault event is not monitored, failure indication
information from the peer is still normally received and processed.
Example: Enable remote failure indication of ethernet 1/4.
Switch(Config-If-Ethernet1/4)#ethernet-oam remote-failure
10.23 ethernet-oam remote-loopback
This command is not supported by switch.
10.24 ethernet-oam remote-loopback supported
This command is not supported by switch.
10.25 ethernet-oam timeout
Command: ethernet-oam timeout <seconds>
no ethernet-oam timeout