Commands for DDM
166
RX Power(dBM) -30.54(A-) 9.00 -25.00(-34) 9.00 -25.00
TX Power(dBM) -1.01 9.00 -12.05 9.00 -10.00
Ethernet 1/22 transceiver threshold-violation information:
Transceiver monitor is disabled. Monitor interval is set to 30 minutes.
The last threshold-violation doesn’t exist.
12.5 transceiver-monitoring
Command: transceiver-monitoring {enable | disable}
Function: Enable/ disable the transceiver monitoring.
Parameter: enable/ disable: Enable or disable the function.
Command Mode: Port mode
Default: Disable.
Usage Guide: None.
Example: Enable the transceiver monitoring of ethernet1/1.
Switch(config-if-ethernet1/1)#transceiver-monitoring enable
12.6 transceiver-monitoring interval
Command: transceiver-monitoring interval <minutes>
no transceiver-monitoring interval
Function: Set the interval of the transceiver monitoring. The no command sets the
interval to be the default interval of 15 minutes.
Parameter: <minutes>: The interval of the transceiver monitoring needs to be set.
Command Mode: Global mode
Default: 15 minutes.
Usage Guide: None.
Example: Set the interval of the transceiver monitoring as 1 minute.
Switch(config)#transceiver-monitoring interval 1
12.7 transceiver threshold
Command: transceiver threshold {default | {temperature | voltage | bias | rx-power
| tx-power} {high-alarm | low-alarm | high-warn | low-warn} {<value> | default}}
Function: Set the threshold defined by the user.
Parameters: default: Restore the threshold as the default threshold set by the