mac

Commands for DDM
167
manufacturer. If the monitoring index is not specified, restore all thresholds, if the
monitoring index is specified, restore the corresponding threshold only.
temperatureThe monitoring indextemperature
voltageThe monitoring indexvoltage
biasThe monitoring indexbias current
rx-powerThe monitoring indexreceiving power
tx-powerThe monitoring indexsending power
high-alarmHigh-alarm of the monitoring index, namely there is alarm with
A+ if exceeding the threshold.
low-alarmLow-alarm of the monitoring index, namely there is alarm with
A- if exceeding the threshold.
high-warnHigh-warn of the monitoring index, namely there is warning
with W+ if exceeding the threshold.
low-warnLow-warn of the monitoring index, namely there is warning with
W- if exceeding the threshold.
Command Mode: Port mode
Default: The threshold is set by the manufacturer.
Usage Guide: The range of the threshold parameters is shown for each monitoring
index in the following:
Temperature: -128.00~128.00
Voltage: 0.00~7.00 V
Bias current: 0.00~140.00 mA
x-power: -50.00~9.00 dBM
tx-power: -50.00~9.00 dBM
The maximum length of the threshold parameter configured by the user is 20 bits.
After the user configured a parameter threshold, the threshold set by the manufacturer
will be labeled with the bracket when showing the threshold, and decide whether give an
alarm according to the user’s configuration.
Example: Configure tx-power threshold of the fiber module, the low-warn threshold is
configured as -12 on ethernet1/1.
Switch(config-if-ethernet1/1)#transceiver threshold tx-power low-warning -12