mac

Commands for ULPP
535
Default: Do not display.
Command mode: Admin mode.
Usage Guide: None.
Example: Show the contents of the receiving flush packets for the port1/1.
Switch# debug ulpp flush content interface e1/1
Flush packet content:
Destination MAC: 01-03-0f-cc-cc-cc
Source MAC: 00-a0-cc-d7-5c-ea
Type: 8100
Vlan ID: 1
Length: 518
Control Type: 2
Control Vlan: 10
MAC number:0
Vlan Bitmap:
52.6 debug ulpp flush {send | receive} interface
Command: debug ulpp flush {send | receive} interface <name>
no debug ulpp flush {send | receive} interface <name>
Function: Show the information of the receiving/sending flush packets, it only shows the
receiving packets, but do not show the detailed contents of the packets. The no
operation disables the shown information.
Parameter: <name> is the name of the port.
Default: Do not display.
Command mode: Admin mode.
Usage Guide: None.
Example: Show the information that send the flush packets for the port1/1.
Switch# debug ulpp flush send interface e1/1
Flush packet send on port Ethernet 1/1.
52.7 description
Command: description <string>
no description
Function: Configure the description character string of ULPP group. The no command
deletes the description.