Owner's manual

5
BATTERY GASES, TESTER PREPARATION
AND TESTER/CHARGER LOCATION
RISK OF EXPLOSION
Gases produced by a battery are highly explosive.
Wear safety goggles and protective clothing, both users and bystanders.
Use in an area having at least four air changes per hour.
Read, understand and follow all instructions for charger, battery, vehicle and
any equipment used near battery and charger.
Do not smoke, strike a match, place metal tools on battery or cause a spark
in the vicinity of the battery. When removing battery cables, remove the
ground cable rst.
Clean terminals before charging battery. During cleaning, keep corrosive
particles from eyes, nose and mouth. Use baking soda and water to neutralize
acid and help eliminate airborne corrosion.
Never allow clamps on charger cables to touch each other.
Do not expose tester or charger to rain, snow, or wet conditions.
Do not allow battery gases or acid to contact MUTT
®
cabinet.
Do not place charger directly above or below battery.
Fill battery to level specied by battery manufacturer using distilled water.
Do not remove cell caps while charging per manufacturer’s instructions.
Make sure tester cable clamps make tight connections.
•Battery explosion can cause injury.
ACID BURNS
• Battery acid is highly corrosive sulfuric acid.
• Wear safety goggles, both user and bystanders.
• Wear safety gloves.
• Make sure someone can hear you or is close enough to provide aid when working
near battery.
• Have plenty of fresh water and soap nearby. If battery acid contacts skin,
clothing or eyes, ush the exposed area with soap and water for 10 minutes.
Seek medical help.
• Do not touch eyes while working near battery.
• Battery acid can burn eyes and skin.