User Manual

4 DEFINITIONS
3.4.2 Back
The single connector at the back side of the µCROS SL is the POWER/CAN/IO Connector.
This connector bundles all the measurement signals and the power supply which usually
are part of the test rig. This feature facilitates fast connect and disconnect of the µCROS
SL from the device under test. The ordering code and the pinout of the connector are
described in section 7.8.3 on page 30.
4 Definitions
Download: data transfer from the µCROS SL to a host.
Upload: data transfer from a host to the µCROS SL�
Web Interface: A set of web pages which are served by the internal webserver of the
µCROS SL at http://203.0.113.1:8080. These pages are the GUI interface for the µCROS SL
settings.
5 Functional description
5.1 Analog Inputs
The analog inputs of the µCROS SL are semi-differential inputs with a input range of ± 2 V
between Analog IN CHx GND and the negative power supply UB- and a range of 0 V to
40 V between Analog IN CHx + and Analog IN CHx GND. The Analog IN CHx GND pins
are independent of each other so a differential voltage between each of the pins as well
as UB- is acceptable as long as it stays within the ± 2 V limit. This design compensates
potential differences between the the µCROS SLs UB- supply and the point of the analog
measurement without compromising the accuracy of the measurement. If the increased
accuracy isnt needed the Analog IN CHx GND pins may be connected to UB- at the
POWER/CAN/IO connector.
Changes and errors excepted. µCROS SL V1.10 EN - 2020/03 10