7.1 GENERAL DATA
7.1.1.3 Back:
Cautions the user to consult the manual for
explanation and/or description of the fea-
ture
POWER/CAN/IO main connector for power supply and signal
input. For pinout refer to 7.8.3 on page 30.
6-36V · · · 30W the allowed voltage range and the maxi-
mum power consumption of the device.
7.1.2 Standards
The µCROS SL meets the following standards:
EN 60 068-2-14:2009
Environment: temperature cycles
EN 60 068-2-27:2009 Environment: shock
EN 60 068-2-64:2008 Environment: vibration
EN 60 529:2014-09 Enclosures: degrees of protection
EN 62 311:2008-09 Human exposition to EM fields
EN 62 368-1:2014+AC2015 electrical safety
EN 300 328 v2.1.1 IEEE 802.11b/g/n
EN 301 489-01 EMC
EN 301 489-17 v3.2.0 EMC WLAN
EN 301 489-19 v2.1.0 GNSS / GPS / ROMES
EN 301 489-52 v1.1.0 UMTS
EN 301 511 v12.5.1 GSM
EN 301 893 v2.1.1 IEEE 802.11a/n 5GHz
EN 301 908-1 v11.1.1 UMTS
EN 303 413:2017-12 GNSS
FCC/ISED test 47 CFR Part 15B unintentional emissions
FCC/ISED test 47 CFR Part 22/24 GSM
FCC/ISED test 47 CFR Part 22/24/27 WCDMA
FCC/ISED test 47 CFR Part 15.247 WLAN 2.4 GHz
FCC/ISED test 47 CFR Part 15.407 WLAN 5 GHz
ISO 16 750-3:2012-12 Road vehicle equipment: mechani-
cal loads
7.1.3 Ambient Conditions
Operating temperature range -20
0
C to +75
0
C
Storage temperature range -40
0
C to 95
0
C
Relativ humidity 0% to 90% non-condensing
Operating height -500 to 5000 m above sea level
Protection rating EN 60529 IP 40
Acceleration EN 60068-2-64:2008
Shock EN 60068-2-27:2009