Users Manual Part 2

4. Inspect the exposed card entry casting and card reader, and use a thin sturdy device to remove all obstructions .
The card reader slot casting and card reader are clear.
5. Reassemble the card entry, and carefully reconnect the keypad to the meter mechanism.
6. Reinstall the meter mechanism into the meter housing.
How To Check the M5 Battery Voltage
This task topic explains how to check the battery voltage on the IPS Group, Inc. M5™ parking meter.
The IPS Group, Inc. SSPM's operate with two batteries. The voltage of each battery can be checked to determine if an individual battery
must be recharged or replaced. This procedure outlines how to properly charge the IPS Group, Inc. M5 SSPM. It is intended for internal
use by IPS personnel, or a customer’s authorized field technicians.
The M5 SSPM uses two different batteries:
75