Installation Guide

I. Opening and Closing the Air Cleaner Housing
Replacing Your HyperHEPA® Filter
The stacked housing elements are held together by two locking arms that hook into the
diffuser. To open the system, follow the steps below.
1. Disconnect the IQAir System from the power supply before at temp ting to open the system.
2. Press the rst locking arm outward, using both thumbs as shown. Press just hard enough to
release the arm from its snap-in position in the diffuser. Disengage the other arm in the same
way.
3. Pull both locking arms evenly outwards until they snap into place and remain open. Access
to all lters is now possible (to change the HEPA lter, refer to section II below).
4. To close the housing, simply align the housing modules and push the locking arms inwards
simultaneously until they snap back into the diffuser.
Opening Closing
Troubleshooting when closing the Housing
If the IQAir System does not close properly, the upper part of the system may
be offset against the lower part. To solve this problem, simply open both
locking arms again, align the housing modules and push both locking arms
in simultaneously.
II. Replacing the HyperHEPA® Filter (F3)
0209/105.01.10.31
1. Open the locking arms, making
sure they are fully extended
outward. For details, refer to the
section I.
2. Opening the arms will release the
top housing modules. Removing
the dif fu ser will reveal the Hyper-
HEPA lter inside Frame 3.
3. Remove Frame 3 containing the
Hyper HEPA l ter.
Frame 3
HyperHEP
lter
Frame 3
Diffuser