Datasheet

AUIPS7091(G)(S)PbF
www.irf.com
3
Absolute Maximum Ratings
Absolute maximum ratings indicate sustained limits beyond which damage to the device may occur. All voltage parameters
are referenced to Ground lead. Tj= -40°C..150°C, Vcc=6..35V (unless otherwise specified).
Symbol
Parameter
Min.
Max.
Units
Vout
Maximum output voltage
Vcc-63
Vcc+0.3
V
Voffset
Maximum logic ground to load ground offset
Vcc-63
Vcc+0.3
Vin
Maximum input voltage
-0.3
5.5
Vcc max.
Maximum Vcc voltage
60
Vcc cont.
Maximum continuous Vcc voltage
35
Vcc sc.
Maximum Vcc voltage with short circuit protection with Tj < -10°C
28
Iin max.
Maximum IN current
-1
10
mA
Idg max.
Maximum diagnostic output current
-1
10
Vdg
Maximum diagnostic output voltage
-0.3
5.5
V
Pd
Maximum power dissipation (internally limited by thermal protection)
1.25
W
Rth=100°C/W
Isd cont.
Maximum continuous diode current (Rth=100°C/W)
1.8
A
ESD1
Electrostatic discharge voltage (Human body) 100pF, 1500
4
kV
ESD2
Electrostatic discharge voltage (Machine Model) C=200pF,R=0,L=10µH
0.5
Tj op max.
Max. operating temperature junction temperature
-40
+150
°C
Tj Sto max.
Max. storage temperature junction temperature
-55
+150
°C
Thermal Characteristics
Symbol
Parameter
Typ.
Max.
Units
Rth1
Thermal resistance junction to ambient SO8 std. footprint
100
°C/W
Rth1
Thermal resistance junction to ambient TO220 free air
60
Rth1
Thermal resistance junction to ambient D2Pak std. footprint
60
Rth2
Thermal resistance junction to ambient D2Pak 1” sqrt. footprint
40
Rth3
Thermal resistance junction to case D2pak/TO220
4
Recommended Operating Conditions
These values are given for a quick design. For operation outside these conditions, please consult the application notes.
Symbol
Parameter
Min.
Max.
Units
VIH
High level input voltage
4
5.5
V
VIL
Low level input voltage
-0.3
0.9
Iout
Continuous drain current, Tamb=85°C, Tj=125°C, Vin=5V, Rth=100°C/W
1.5
A
Rin
Recommended resistor in series with IN pin
10
20
k
Rdgs
Recommended resistor in series with DG pin
10
20
Rol
Recommended pull-up resistor for open load detection
5
100