Table 7: Iridium Core 9523N Environmental Tests
Test Name
Test Reference
Test Description
IEC
Change of Temperature
(EN60068-2-14 2009)
Five cycles of 1 hour each from -30°C to +70°C.
Mechanical Shock
(EN60068-2-27 2009)
Mount unit on a vibration table and excite with three half
sine pulses in each of three axis (pulse peak amplitude:
10g, pulse duration: 11ms).
Vibration
(EN60068-2-64 2008)
Mount unit on a vibration table and excite from 5Hz to
20Hz at 0.96m
2
/s
3
and from 21Hz to 500Hz at
0.96m
2
/s
3
rolling of at -3dB per octave for 1 hour per
axis in each of three axes.
Damp Heat Steady State
(EN60068-2-78 2012)
40°C, 93%RH for 4 days
SAE
Thermal Shock
SAE J1455:2012 Section 4.1.3.2
Five cycles of 2 hours each from -40°C to +85°C.
Handling Drop Test
SAE J1455:2012 Section
4.11.3.1
Drop from a height of 1m onto a concrete surface, one
time in each of the three mutually perpendicular planes
(three drops in total).
SAE J1455:2012 Section
4.10.4.2 Vibration
Mount unit on a vibration table and excite from 10 Hz to
40 Hz at 0.02g²/Hz and from 40 Hz to 500 Hz at
0.02g²/Hz dropping of at -6 dB per octave for 1 hour per
axis in each of three axes.
MIL-STD-810G
Low Pressure
Method 500.5
Procedure II - Operation/Air
Carriage
Decrease pressure to 57.2 kPa (equivalent to 15,000
feet) at a rate not to exceed 10 m/s at a temperature of
23ºC ±3ºC and hold for 1 hour.
High Temperature
Method 501.5
Procedure I Storage
Over 24 hours, cycle the unit from 35ºC to 71ºC and
back to 35ºC. Repeat 7 times.
High Temperature
Method 501.5
Procedure II - Operation
This test is a subset of the High Temperature test
(Method 500.5, Procedure I) in which the operation is
verified at 71ºC over the first 3 cycles of Procedure I.
Low Temperature
Method 502.5
Procedure I Storage
Ramp from ambient conditions to -45ºC ±2ºC in 1 hour.
Soak at -45°C for 24 hours.
Ramp from -45°C to ambient conditions in 1 hour.
Low Temperature
Method 502.5
Procedure II Operation
Ramp from ambient conditions to -10ºC ±2ºC in 1 hour.
Soak at -10°C for 24 hours.
Ramp from -10°C to ambient conditions in 1 hour.
Temperature Shock
Method 503.5
Procedure I-C
Soak at -40ºC for 4 hours. Transfer to +85ºC and soak
for an additional 4 hours. Repeat 4 times (4 cold to hot
transitions and 4 hot to cold transitions).
Humidity
Method 507.5
Procedure II Aggravated
Held at 95% RH with the ambient temperature changed
from 30°C to 60°C and then down to 20°C over a 48
hour cycle, with the cycle repeated 5 times.
Vibration
Method 514.6
Procedure I General Vibration
(Category 8)
Secure unit to a vibration table and excite randomly
with the following profile: Category 8:15-2000 Hz,
L
0
=0.30 g
2
/Hz, f
0
= 68 Hz, 1 hour per axis in each of 3
axes.
Shock
Method 516.6
Procedure I Functional Shock
Expose unit to 3 shocks of 40g over approximately
11ms in +/- direction of each of the 3 primary axes (18
total shocks).