Ground Mount Installation Guide
Table Of Contents
- DISCLAIMER
- RATINGS
- MARKINGS
- Checklist
- 1. Build Base
- 2. Connect Substructure
- 3. Place Rails
- 4. SECURE LUGS
- 5. Secure MODULES
- CAMO
- Electrical Diagram
- Diagonal Braces (Optional)
- END CAPS
- Wire Clips
- Splicing Cross Pipe
- Microinverter Kits
- systems using Enphase Microinverters or Sunpower AC Modules
- SYSTEMS USING PHAZR MICROSTORAGE PRODUCTS
- Frameless MODULE Kits
- MODULE COMPATIBILITY
- Module Compatibility
- Module Compatibility
GROUND MOUNT INSTALLATION MANUAL - 2©
2019 IRONRIDGE, INC. VERSION 2.1
RATINGS
MARKINGS
Product markings are located on the system’s Rail
Connectors.
UL 2703 LISTED
• Conforms to STD UL 2703 (2015) Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/
Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels.
• Conforms to Canadian requirements LTR AE-001-2012 Photovoltaic Module Racking Systems.
• Max Overcurrent Protective Device (OCPD) Rating: 25A
• Max Module Size: 24ft²
• Max Frameless Module Size for Canadian LTR-AE: 19.5 ft²
• CAMO Specic Allowable Design Load Rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral
• LTR AE Canadian Load Rating: 2400 Pa
• System Level Allowable Design Load Rating: meets minimum requirements of the standard (10 PSF downward, 5
PSF upward, 5 PSF lateral). Actual system structural capacity is dened by PE stamped certication letters.
CLASS A SYSTEM FIRE RATING PER UL 1703
• Not Fire Rated
STRUCTURAL CERTIFICATION
• Designed and Certied for Compliance with the International Building Code & ASCE/SEI-7
#5003225