BX SYSTEM INSTALLATION MANUAL
Contents DISCLAIMER RATINGS MARKINGS CHECKLIST OVERVIEW INSTALLATION STEPS (QUICK GUIDE) 1. MARK LAYOUT 2. PLACE CHASSIS 3. MOUNT MLPE (OPTIONAL) 4. LAY BALLAST 5. ANCHOR SYSTEM (OPTIONAL) 6. INSTALL MODULES 7. COMPLETE BONDING 8. PV MODULE GROUNDING LUGS STRING INVERTER MOUNTING KIT (OPTIONAL) ELECTRICAL DIAGRAM MODULE COMPATIBILITY 1 2 2 3 4 5 6 6 6 7 7 8 8 9 9 10 10 DISCLAIMER This manual describes proper installation procedures and provides necessary standards required for product reliability.
RATINGS UL 2703 LISTED #5014158 • Conforms to STD UL 2703 (2015) Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/ Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. • Max Overcurrent Protective Device (OCPD) Rating: 25A • Max Module Size: 24ft² • Module Orientation: Landscape • System Level Allowable Design Load Rating: 30 PSF downward, 20 PSF upward, 5 PSF lateral.
CHECKLIST PRE-INSTALLATION COMPONENTS ☐ Verify module compatibility. See Page 9 for info.
OVERVIEW BX CHASSIS (5° & 10°) BX Chassis is designed to clamp PV modules and secure them in place. Reference tabs are integrated to aid with aligning modules according to system layout. The Chassis is available in two SKUs: 5 and 10 degree tilt configurations. The Chassis is designed to accommodate 4 full size (16” x 8” x 4”) or 8 half-size concrete ballast blocks (16” x 8” x 2”) nominal dimensions.
INSTALLATION STEPS (QUICK GUIDE) 1. Mark out all fire setbacks on the roofing plane. 2. Measure and mark out footprint of array according to the approved planset location. 3. Starting at the south edge of the approved planset, chalk the South Array Edge, making sure that this line is at least 8" away from the South Fire Setback. 4. Measure Chassis spacing (refer to chart below) and chalk out 3 rows, 25’ each. 5. Measure out the Chassis locations by marking along each row, module width plus 3/8”. 6.
1. MARK LAYOUT Using the approved planset, mark out all fire setbacks and the array foot print on the roof(s). Mark the South Array Edge with a 25' line (for example). If the southern edge of the array is against the South Fire Setback, mark the South Array Edge at least 8" away from the setback. This will ensure that no part of the Chassis is in the setback. Measure Chassis spacing (refering to table on Page 5) and chalk out 3x 25' rows.
4. LAY BALLAST Place ballast blocks in BX Chassis as indicated on site layout. 5. ANCHOR SYSTEM (OPTIONAL) A. SECURE L-FEET A The Attachment Kit uses an 8' minimum Strut Channel to span across two Chassis and a FRA Anchor in order to anchor the Chassis to the roof. Secure L-Feet onto the Chassis by installing the Carriage Bolt and Square Washer from the underside of each Chassis through the reference hole. Torque Flange Nut to 120 in-lbs.
6. INSTALL MODULES A. PLACE CLAMPS A Place Bottom Clamp over the Chassis' corner bolt, then pull clamp towards the outer edge. íí The north end of the North Row and south end of the South Row do not need bottom clamps. B. LAY MODULES B Lay Module onto Bottom Clamps Starting in the South-West corner and working east, lay modules in a row onto edge of Bottom Clamps. Doublecheck panel spacing along each row. íí You can use reference tabs located in the middle of the Chassis to properly space modules.
7. COMPLETE BONDING (CONTINUED) B. ROW-TO-ROW BONDING B Complete row-to-row bonding using the 38” Row Bonding Jumper by securing Clips to inner flanges on long side of a module from each row, as shown. Tapping Clips into place may be required for modules with thicker flanges. íí The bonding does not need to take place on the same side of the array, so long as every row is bonded to the next row. 8.
ELECTRICAL DIAGRAM MODULE COMPATIBILITY The BX System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, “xxx” refers to the module power rating and both black and silver frames are included in the certification.
MODULE COMPATIBILITY (CONTINUED) Flex Modules with 35, 40, or 50mm frames and model identifier FXS-xxxYY-ZZ; where "xxx" is the module power rating; "YY" is BB or BC; and "ZZ" is MAA1B, MAA1W, MAB1W, SAA1B, SAA1W, SAC1B, SAC1W, SAD1W, SBA1B, SBA1W, SBC1B, or SBC1W. GCL Modules with 35 and 40mm frames and and model identifier GCL-a6/YY xxx; where "a" can be M or P; and "YY" can be 60, 72, or 72H. GigaWatt Solar Modules with 40mm frames and model identifier GWxxxYY; where “YY” is either PB or MB.
MODULE COMPATIBILITY (CONTINUED) REC Solar Renesola Renogy S-Energy Seraphim Energy Group Seraphim USA Sharp Silfab Modules with 30, 38 and 45mm frames and model identifier RECxxxYYZZ; where “YY” can be M, NP, PE, TP, TP2, TP2M, TP2SM, or TP2S; and “ZZ” can be blank, Black, BLK, BLK2, SLV, or 72. Modules with 35, 40 or 50mm frames and model identifier JCxxxY-ZZ; where "Y" is F, M or S; and "ZZ" is Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b.