2021 IRONRIDGE, INC. VERSION 3.1 FLUSH MOUNT INSTALLATION MANUAL - 4
COMPONENTS
BONDING HARDWARE TORQUE VALUES
Please refer to each attachment's individual section for full details 
on all torque values and instructions. 
 ☐ Bonded Splice Screws (5/16" Socket): 20 in-lbs
 ☐ Universal Fastening Object (7/16" Socket): 80 in-lbs
 ☐ Rail Grounding Lug Nut (7/16" Socket): 80 in-lbs 
 ☐ Grounding Lug Terminal Screws (7/16" Socket): 20 in-lbs
 ☐ Module Grounding Lug Nut (3/8" Socket): 60 in-lbs
 ☐ Grounding Lug Terminal Screws (1/2" Socket): 20 in-lbs
 ☐ Expansion Joint Nuts (7/16" Socket): 80 in-lbs
 ☐ Microinverter Kit Nuts (7/16" Socket): 80 in-lbs
 ☐ Frameless Module Kit Nuts (7/16" Socket): 80 in-lbs
 ☐ 3/8" Bonding Hardware Nuts (7/16" Socket): 250 in-lbs
COMPONENTS
Bonded SpliceXR Rail
UFO and Stopper 
Sleeve 
CAMO
Rail Grounding Lug
8" Bonding Jumper
Expansion Joint
Wire Clip
End Cap
QMPV QBOX
3/8" Bonding
Hardware
Microinverter Kit
Frameless Module Kit
Frameless 
End/Mid Clamp
QMPV Classic 
Conduit Comp Mount 
QMPV Composition 
Conduit Penetration
QMPV Tile Conduit 
Mount
QMPV Tile Conduit 
Penetration
PRE-INSTALLATION
 ☐ Verify module compatibility. See Page 21 for info.
TOOLS REQUIRED
 ☐ Cordless Drill (non-impact)
 ☐ Impact Driver (for lag bolts)
 ☐ Torque Wrench (0-250 in-lbs)
 ☐ 7/16” Socket
 ☐ 1/2" Socket
 ☐ 9/16" Socket
 ☐ 7/32" Drill bit
 ☐ 1/8" Drill bit
 ☐ 1/4" Drill bit
 ☐ T30 Bit
 ☐ Channel Lock Pliers
 ☐ #3 Phillips Bit
 ☐ Paddle Bit
Ironridge L-Foot
BOSS
Module Grounding 
Lug