5. INSTALL MODULES
B. ATTACH NORTH EDGE
Once module is almost parallel to the roof, align mount
with hanger bolt and pivot onto the north edge of the
module.
Secure mount to the ashing using the hanger nut. Torque
to 132 in-lbs.
C. PLACE REMAINING MODULES IN ROW
Place the second module in the clamp of the mount and
bridge, and position it so that the edges are ush with the
spacers on either side.
Rotate the module downward and apply pressure towards
the mount and bridge to ensure that module slides into
place and is properly seated.
B
7/16" socket
132 in-lbs
C
Spacers