Install Manual

GROUND MOUNT INSTALLATION MANUAL - 6© 2021 IRONRIDGE, INC. VERSION 3.1
3. PLACE RAILS
A. ATTACH HARDWARE
On the ground, attach Rail Connector brackets to rail by


tighten Flange Nuts onto bolts.
Tape ends of rail, to keep bolts from sliding out while moving.
B. FASTEN CONNECTORS
Center Rails on horizontal beams, leaving equal distance


Torque U-bolt nuts to 60 in-lbs and bracket to 21 ft-lbs.
Spacing between rails should align with module manufacturer
recommended clamping locations.
4. SECURE LUGS
A
U-Bolt
60 in-lbs
Bracket

Hex Nut
(84 in-lbs)
Terminal Screw
(20 in-lbs)
Hex Nut
(80 in-lbs)
B
FLANGE NUT
GROUNDING LUG
BOLT
STAR WASHER
Terminal Screw
(20 in-lbs)
Hex Head
(60 in-lbs)
Module Grounding Lug
Rail Grounding Lug
Grounding Lugs

subarray, regardless of subarray size (Unless frameless modules are
used, see 3).
Grounding Lugs are intended to for use with one solid or
stranded copper wire, conductor size 10-4 AWG.
Rail Grounding Lug
Insert T-bolt in Top Rail slot and torque Hex Nut to 80 in-lbs. Install

terminal screw to 20 in-lbs.
Rail Grounding Lugs can be installed anywhere along the Rail and
in either orientation shown.
Module Grounding Lug
Insert Bolt through Module Manufacturer approved grounding location
and torque Hex nut to 60 in-lbs.

solid copper or stranded grounding wire. Torque terminal screw to 20
in-lbs.
If using Enphase microinverters or Sunpower AC modules,
Grounding Lugs may not be needed. See Page 12 for more info.
Refer to module manufacturer manual for grounding instructions.