Datasheet

Jan-2017, Rev 9BI 7.2.3-8
Sources: APA - The Engineered Wood Association, TT-051C, 2011
Note: Lag pull-out (withdrawal) ultimate capacity = 350 lbs. in 1/2" plywood or 1/2" OSB.
IMPORTANT: To maintain waterproong it is important that the aluminum ashing (item 1) is properly placed under one full course above the mounting block with at least some of the
ashing extending up under the course above that as well. See instructions on back.
9.0
12.0
2.5
4.5
1.31
2.38
THIS EDGE TOWARDS ROOF RIDGE
.79
.04
1.46
3
4
CONDUIT CLAMP
NOT INCLUDED
1
2
AVAILABLE IN MILL FINISH, AND
BRONZE ANODIZED FINISH.
ITEM
NO.
DESCRIPTION
QTY.
1
FLASHING, 9" X 12" X .040", 5052, MILL
1
2
QBLOCK, CONDUIT, 5/16", CAST A360 AL, MILL
1
3
WASHER, SEALING, 1/4" ID X 1" OD, EPDM
BONDED SS
1
4
LAG SCREW, HEX HEAD, 1/4" x 2-1/2", 18-8SS
1
6
DO NOT SCALE DRAWING
SHEET 1 OF 1
RAD
SCALE: 1:3
WEIGHT:
REV
A
SIZE
TITLE:
DATE:
DRAWN BY:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/8
TWO PLACE DECIMAL
.18
THREE PLACE DECIMAL
.125
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS
A WHOLE WITHOUT THE WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED.
5
4
3
2
1
UNLESS OTHERWISE SPECIFIED:
0.62
QMCC: CLASSIC CONDUIT
COMPOSITION MOUNT
5/3/2016
Lag pull-out (withdrawal) design values (lbs) in typical sheathing:
Lag Bolt Specications
Specic Gravity 1/4" shaft per 1/2" thread depth 1/4" shaft per 1" thread depth
Plywood .45 72 144
OSB .45 72 144