Datasheet

BI7.2.3-14
Aug-2019, Rev 12
QBase
®
Shake & Slate Mount | QMNS
18.00
18.00
9.00
6.50
THIS EDGE TOWARDS ROOF RIDGE
1.90
FLASHING HEIGHT
(ITEMS 4 & 5)
2.50
2.00
NOTES:
1
POST AND FLASHING AVAILABLE IN MILL FINISH,
AND BRONZE ANODIZED FINISH
2
FLASHING MAY BE SPUN OR PRESSED
3
STAINLESS STEEL LAG SCREWS INCLUDED WITH
ANODIZED FINISH
1.250
1.500
3.750 .500
QBASE (ITEM 2) AND
POST (ITEM 6)
4.000
4X
.32 THRU
(CLEARANCE FOR
5/16" HARDWARE)
2.500
1
2
3
4
6
7
8
5
1
1 2
3
ITEM
NO.
DESCRIPTION
QTY.
1
CAP SCREW, HEX HEAD, 5/16"-18 X 3/4" UNC-2A, GRADE 8,
MAGNI
1
2
QBASE, 1-1/4" ID, FOR 5/16" HARDWARE, A360 CAST AL
1
3
LAG SCREW, HEX HEAD, 5/16" X 3", ZINC
2
4
FLASHING, CONE, 18"X18"X.032", 3003 AL, MILL
1
5
COLLAR, COUNTER FLASHING, 1-1/4" ID EPDM
1
6
POST, 1-1/4" OD X 3-1/4", 6063-T5/6063-T6, MILL
1
7
WASHER, SEALING, 5/16" ID X 1-1/4" OD, EPDM BONDED SS
1
8
CAP SCREW, 5/16"-18 X 1" UNC-2A, NYLON PATCH, W/ CAPTIVE
WASHER, 1"OD, 18-8 SS
1
14
DO NOT SCALE DRAWING
SHEET 1 OF 1
RAD
SCALE: 1:8
WEIGHT:
REV
A
SIZE
TITLE:
DATE:
DRAWN BY:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/8
TWO PLACE DECIMAL
.19
THREE PLACE DECIMAL
.094
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED.
COPYRIGHT © 2019 QUICK MOUNT PV
5
4
3
2
1
UNLESS OTHERWISE SPECIFIED:
1.94
QMNS: QBASE METAL, SHAKE
AND SLATE MOUNT
8/9/2019
PLEASE NOTE: Cedar shakes treated with ACQ or CCA wood preservatives or fire retardant chemicals, or shakes with higher
concentrations of natural tannins, may cause accelerated corrosion when in direct contact with aluminum. The Cedar Shingle
& Shake Bureau recommends pre-painting both sides of the flashing using a good metal or bituminous paint. It is also
advisable to use an appropriate physical barrier to isolate the aluminum from these corrosive chemicals. Accepted barriers
include standard roofing felt, ice & water shield type underlayment, or 10 mil thick polyethylene sheeting. Please check with
your shake roofer and/or supplier to see if your shakes require these barriers.
Caution: Prior to installation, check that proper screw embedment will be achieved for the necessary site load and roofing
configurations.

Summary of content (4 pages)