Datasheet

Isabellenhütte Heusler GmbH & Co. KG // sales.components@isabellenhuette.de // Issue 13-Dezember-2018// Current valid issue: see www.isabellenhuette.de
5 / 5
ISA-PLAN
®
// PRECISION RESISTORS
SMT // Size 2817
0,0001
0,001
0,01
0,1
1
10
100
0,01
0,1
1
10
100
1000
10000
0,0001 0,001 0,01 0,1 1 10 100
SMT-R004, SMT-4R70
Maximum pulse energy / power for continuous operation (T
K
= 105 °C)
Disclaimer // All products, product specifications and data are subject to change without notice.
The product specifications do not expand or otherwise modify Isabellenhütte’s terms and conditions of sale, including but not limited to, the war-
ranty expressed therein. Isabellenhütte makes no warranty, representation or guarantee other than as set forth in its terms and conditions of sale.
Information provided in datasheets and/or specifications may vary from actual results in different applications. Any statements made by Isabel-
lenhütte regarding the suitability of products for certain types of applications are based on its knowledge of typical requirements that are often
placed on its products. It is the customer’s responsibility to validate that a particular product with the properties described in the product specifi-
cation is suitable for use in the application intended.
No license, express or implied, or otherwise, to any intellectual property rights is granted by this document.
Any and all liability arising out of the application or use of any product shall be as set forth in Isabellenhütte’s terms and conditions of sale.
Maximum pulse energy respectively pulse power for permanent operation
Pulse energy [J]
Pulse width [sec]
Power [W]
100010000
Specication
Parameters Test conditions Specied values
Temperature Cycling 2000 cycles (-55 °C to +150 °C) ±0.5%
Low Temperature Storage and Operation -65 °C for 250 h ±0.1%
Resistance to Soldering Heat 260 °C for 10 sec / 8h steam aging ±0.3%
Moisture Resistance MIL-STD-202 method 106 ±0.1%
Mechanical Shock 100 g, 6 ms half sine ±0.1%
Vibration, High Frequency 20 g, 10-2000 Hz ±0.1%
Operational Life 2000 h, T
K
max at rated power ±1.0%
High Temperature Exposure 2000 h / 170 °C ±1.0%
Bias Humidity +85 °C, 85 r.F., 1000 h ±0.5%