P10 User Manual

Preset Battery Type of Charger and Task Parameters
Rated voltage
Full charge voltage
Balance charge
Unbalanced charge
Supported cell count
Max. charging current
NiCd/MH Pb LiFe Lilon LiPo LiHv
3.60V
4.10V
1~6S
10.0A
3.20V
3.65V
1-6S
10.0A
3.70V
4.20V
1~6S
10.0A
3.80V
4.35V
1~6S
10.0A
1.20V
1.40V
1~16S
10.0A
2.00V
2.40V
1~10S
10.0A
Make sure to know the maximum charging current of the battery before charging, never
use excessive current to charge to damage your battery, which will result in over heat
even explosion during the charging process.The charging and discharging capacity of
battery is usually marked with C value. Multiplying the charging C value and battery
capacity equals to the maximum charging current supported by the battery. For example,
for a 1000 mAh battery with a charging capacity of 5C, the maximum charging current
would be 1000*5=5000mA; therefore, the maximum charging current is 5A.
For a lithium battery, if it is impossible to confirm the supported charging C value, please
set the charging current below 1C, for the sake of its (lithium battery) safety.
The reference relation between C value and charging time: charging time ≥60 minutes/
charging C value (e.g. it needs around 60-70 minutes to complete charging with 1C).
Due to differences in battery conversion efficiency, the time to complete the charging
might be extended.
How to Confirm Charging Current