D1 Touch Screen 1~6S 250W 10A AC/DC Smart Balance Charger/Discharger User Manual

Make sure to know the maximum charging current of the battery before charging, never use excessive current to charge to
damage your battery, which will result in over heat even explosion during the charging process.
The charging and discharging capacity of battery is usually marked with C value. Multiplying the charging C value and battery
capacity equals to the maximum charging current supported by the battery. For example, for a 1000mAh battery with a charging
capacity of 5C, the maximum charging current would be 1000*5=5000mA; therefore, the maximum charging current is 5A.
For a lithium battery, if it is impossible to confirm the supported charging C value, please set the charging current below 1C,
for the sake of its (lithium battery) safety.
The reference relation between C value and charging time: charging time ≥60 minutes/ charging C value
(e.g. it needs around 60-70 minutes to complete charging with 1C).
Due to differences in battery conversion efficiency, the time to complete the charging might be extended.
How to Confirm Charging Current
Power on D1 smart charger, connect the battery, and short press the middle button to enter the task setting menu as follows:
Operating the Charger
Task
Battery
Battery and cell count
Current
Charge, Discharge, Destroy, DC power supply, storage
LiHv、LiPo、LiIon、LiFe、Pb、NiMh/Cd
LiFe,LiIon,LiPo,LiHv (1~6S) ; Pb (1~12S) ; NiMH/Cd (1~16S)
0.1~10.0A
Charge
Balancing port is strongly recommended when charging lipo battery, which can make sure to monitor voltage on each cell
battery and balance it when charging.
Warning beeper will yell before start charging lipo if in non-balance mode (no connecting with balance port).
Current setting range: 0.1~10A
The battery type, cell count and charging current are auto set accordingly when connecting with BattGo battery.
Discharge
Current setting range: 0.1~1.0A
The battery type, cell count and discharging current are auto set accordingly when connecting with BattGo battery.
Destroy
Connect the battery to be scrapped, and select the scrap function in task options, which capable to discharge the battery to 0V.
Current setting range: 0.1~1.0A